Bryant 355MAV manuals
Household Appliance > Furnace
When we buy new device such as Bryant 355MAV we often through away most of the documentation but the warranty.
Very often issues with Bryant 355MAV begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Furnace Bryant 355MAV is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Furnace on our side using links below.
12 pages 298.74 Kb
USERS INFORMATION MANUAL MODEL 340MAV, 350MAV, 352MAV, 355MAV CONDENSING GAS FURNACEThis manual must be left with the equipment user. NOTE TO INSTALLER:2 WELCOME TO A NEW GENERATION OF COMFORTGENERAL FURNACE SAFETYCongratulations! In light of rising energy costs, the Plus 90 , 340MAV, Plus90t and Plus 90i MODELS 340MAV (SHOWN) AND 350MAV FIXED-CAPACITY FURNACES MODEL 355MAV VARIABLE-CAPACITY AND MODEL 352MAV TWO-STAGE FURNACES 3 FURNACE COMPONENTS MODELS 340MAV, 350MAV, AND 352MAV FURNACES (UPFLOW POSITION) MODEL 355MAV FURNACE (UPFLOW POSITION) 4 SAFETY CONSIDERATIONS BEFORE STARTING YOUR FURNACE STARTING AND SHUTTING DOWN YOUR FURNACE 5 STEPS FOR STARTING YOUR FURNACE 12 10 8 9 11 13 14 17 22 19 18 20 SHUTTING DOWN YOUR FURNACE 21 6 PERFORMING ROUTINE MAINTENANCE 9 COMBUSTION AREA AND VENT SYSTEM37 38 39 HEADING SOUTH FOR THE WINTER? DANGER 10 A CHECK-UP CHECKLIST BEFORE YOU REQUEST A SERVICE CALL
Also you can find more Bryant manuals or manuals for other Household Appliance.
Bryant 355MAV Instruction Manual
48 pages 1.02 Mb
ama installation, start-up, and operating instructionsDELUXE 4-WAY MULTIPOISE VARIABLE-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 355MAV Series H3 Fig. 2Dimensional DrawingDIMENSIONS (IN.)combination of 1 side and the bottom, or the bottom only will ensure adequate literature for specific use of single side inlets. The use of both side inlets, a d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data c. For 1600 CFM22-in. round or 14 b. For 1200 CFM20-in. round or 14 a. For 800 CFM16-in. round or 14 NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,* These dimensions reflect the wider casing for the Trophy (96.6 percent AFUE) furnace. 060100 21 19-3/8 19-1/2 060080 21 19-3/8 19-1/2 042080 21 19-3/8 19-1/2 042060 17-1/2 15-7/8 16 042040* 24-1/2* 22-7/8* 23* UNIT SIZE A D E 060120 24-1/2 22-7/8 23 x 23 x 19 x 12-in. rectangle. -in. rectangle. return air openings for airflow requirements above 1800 CFM. * MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION 4 *INSTALLATION15 TABLE 1OPENING DIMENSIONS (IN.)Fig. 19Floor and Plenum Opening Dimensions Fig. 20Furnace, Plenum, and Subbase Installed on a Combustible Floor Fig. 21Furnace, Plenum, and Coil Assembly or Coil Box Installed on a Combustible Floor 22 Fig. 31Unit Wiring Diagram A02291NOTES: CONNECTION DIAGRAM D N E G E L 327971-101 REV.APCB TO 115VAC FIELD-DISCONNECT SWITCH 12. Blower motor (BLWM) and Inducer mot or (IDM) are locked-rotor overload protected by redundan t 8. Factory connected wh en (LGPS) not used. 7. Inductor is used with 3/4 hp and 1 hp ECM Blower motors. 6. Replace only wit h a 3 amp fuse. 5. Solid line s inside PCB are printed cir cuit board conductors and are not included in legend. 4. Symbols are electrical representation only. 3. This wire must be connected to furnace sheet metal for control to prove flame. 2. Use only copper wire between the disconnect switch and the furnace junction box (JB). 1. If any of the or iginal equipment wire is replaced use wire rated for 105C. electronic control ci rcuits. SCHEMATIC DIAGRAM CPU 23 Fig. 32Control Center A02278TABLE 5APPROVED COMBUSTION-AIR AND VENT PIPE, FITTING AND CEMENT MATERIALS 26 TABLE 7MAXIMUM ALLOWABLE PIPE LENGTH (FT)27 TABLE 7MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued30 Fig. 40Sidewall Termination of 12 in. or MoreFig. 37 Roof Termination (Preferred) Fig. 38Concentric Vent and Combustion-Air Roof Termination (Preferred) Fig. 41Sidewall Termination of Less than 12 in. Fig. 39Concentric Vent and Combustion-Air Side Termination 39 Notes for Fig. 50-57:41 1OFF
60 pages 1.03 Mb
ama Installation, Start-up, and Operating Instructions355MAV Series F Deluxe 4-Way Multipoise Variable-Capacity Direct-Vent Condensing Gas Furnace4 Fig. 2Dimensional DrawingDimensions (in.)NOTES: 1. Minimum return-air openings at fur nace, based on metal duct. If flex duct is used,060100 21 19-3/8 19-1/2 060080 21 19-3/8 19-1/2 042080 21 19-3/8 19-1/2 042060 17-1/2 15-7/8 16 042040* 24-1/2 22-7/8 23* UNIT SIZE A D E 060120 24-1/2 22-7/8 23* These dimensions reflect the wider casing for the Trophy (96.6 percent AFUE) furnace. A99112 combination of 1 side and the bottom, or the bottom only will ensure adequate literature for specific use of single side inlets. The use of both side inlets, a d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data x 23 c. For 1600 CFM22-in. round or 14 x 19 b. For 1200 CFM20-in. round or 14 a. For 800 CFM16-in. round or 14 x 12-in. rectangle. -in. rectangle. return air openings for airflow requirements above 1800 CFM. Fig. 3Clearances to Combustibles * 5 *30 MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION INSTALLATION 49 1OFF
Also you can find more Bryant manuals or manuals for other Household Appliance.