DKS Enterprises 6500 manuals
Baby > Safety Gate
When we buy new device such as DKS Enterprises 6500 we often through away most of the documentation but the warranty.
Very often issues with DKS Enterprises 6500 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Safety Gate DKS Enterprises 6500 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Safety Gate on our side using links below.
DKS Enterprises 6500 Manual
48 pages 6.03 Mb
1 Vehicular Swing Gate Operator3 Model 6500 - UL325 Class I, II, IIIVehicular Swing Gates Only 1/2 or 1 HP 1/2 HP - 600 Lbs.; 1 HP - 800 Lbs 1/2 HP - 18 Ft.; 1 HP - 22 Ft 60 Per Hour 90° in approximately 12-14seconds Primary - Inherent entrapment sensing system (Type A) This manual is for 6500 operators manufactured after July 12 31 5/8” 31” 28 3/8” 18 3/8” 23 1/4” Use this manual with the following models only: *Optional Convenience Open System 4 GlossaryAuxiliary Device Wiring 6 www.astm.orgWARNING - To reduce the risk of injury or death: 1.READ AND FOLLOW ALL INSTRUCTIONS Always keep people and objects away from gate 5.Use the emergency release only when the gate is not moving 7.The entrance is for vehicles only. Pedestrians must use separate entrance 8.SAVE THESE INSTRUCTIONS •Install the gate operator only if: 3.All exposed pinch points are eliminated or guarded 4.Guarding is supplied for exposed rollers •For gate operators utilizing Type D protection: 2.A warning placard shall be placed adjacent to the controls 4.No other activation device shall be connected The Stop and/or Reset button must be located in the •For gate operators utilizing a non-contactsensor: See the instructions on the placement of One or more 7 •For gate operators utilizing contact sensors:•Pinch points •Entrapment areas •Reach through hazards •Absence of entrapment protection devices •Improperly located access controls •Absence of vehicle protection devices •Absence of controlled pedestrian access Loops and loop detectors •Follow the recommended maintenance schedule Do not allow children to play in the area of the operator or to play with any 8 ClassClass UL325 Horizontal Slide, Vertical Lift, Vertical Pivot Swing and Vertical Barrier (arm) Classifications Primary Protection Class I and Class A- Inherent entrapment protection system C- Inherent adjustable clutch or pressure relief device E- An inherent audio alarm 9 GATERESIDENTIAL VEHICULAR GATE OPERATOR – CLASS multi-family VEHICULAR BARRIER (ARM) OPERATOR (OR SYSTEM) VEHICULAR SWING-GATE OPERATOR (OR SYSTEM) SYSTEM WIRED CONTROL WIRELESS CONTROL INHERENT ENTRAPMENT PROTECTION SYSTEM EXTERNAL ENTRAPMENT PROTECTION DEVICE ENTRAPMENT 10 (ref. UL325 56.8.4.b)Closed Gates Closed Gate If space is less than 16 inches entrapment protection in this area is required. ASTM F2200 and Not Allowed 11 Non-contactSensorReverse Loop Minimizes the potential Minimizes the potential of the gate of the gate closing on vehicular or other traffic closing when a vehicle is present that loops cannot sense Number and placement of loops is dependent on the application Warning Signs Shadow Loop Permanently mounted Provides a hold open command to and easily visible from the operator(s) only if the gate(s) either side of the gate are at the full open position Automatic Exit Loop Separate Pedestrian Walkway 12 PrimarySecondary Position Primary/Secondary Interconnection Cable (Dual Operator Application Only) Low Voltage Control and/or P.A.M.S. Wires Loop Lead-InWires High Voltage Power Sweeps 3/4 Inch Minimum •We suggest that minimum 3/4-inchconduit be used •Be sure that all conduits are installed in accordance with local codes Conduit Location CAUTION 28” Concrete Pad Length 4” minimum 22” 22” Concrete Pad Width 13 90°22” Concrete Pad Location Operator Installation 14 29.5”Operator Installation Operator Installation 15 ARelease hub with release tool. DO NOT REMOVE HUBBBolt crank arm to operator CSlide elbow assembly on crank arm DBolt control arm to gate bracket Slide control arm into elbow assembly. KEEP ARM ASSEMBLY LEVEL Bolt gate bracket to gate Gate Arm assembly and gate bracket MUST Bracket be level for gate to function correctly Control Arm Gate Bracket Crank Arm 17 This table illustrates the high voltage wire size and distance requirementsModel Voltage Amps Wire Size / Distance in Feet Type Required 12 AWG 10 AWG 8 AWG 6 AWG Reduce the wire distance in half for primary/secondary dual gate applications DANGER Chassis Ground Hot • Route incoming high voltage power through conduit and into the operator as shown • Be sure wiring is installed in accordance with local codes. Be sure to color code all wiring Chassis Ground protect the operator and circuit For 230 and board from surges and power fluctuations Volt 3-phase input, use only • Secondary operator in a dual two legs of the operator application gets power through the 8-wireconnector that power connection 18 dependent on the specific installation requirementsbe provided by non-contactor contact sensors, or a Open direction non-contactsensor combination of both Secondary device wiring shows inputs to the circuit Gate resumes normal operation when board only. Photo-cellsmust be supplied with power the obstruction is cleared for more information • Controls must be installed a minimum of 10-feetfrom Close direction non-contactsensor the gate or installed in such a way that the person Reverses gate during the closing using the control cannot come in contact with the gate cycle only. Holds gate in the full open or gate operator position until obstruction is cleared Radio Receiver power only power only Power is limited to 250 ma Remote Terminal Terminal 6 reverse input switch 5 is OFF Magnetic Lock Power (24-VoltDC) and logic switch Fire Box Telephone Entry Key Switch Stand-Alone Keypad Card Reader 19 Loop detector wiring is shown for DoorKingLoop layout shown is for a typical swing gate application with www.dkaccess.com Note: SW 1 switches 5 7 and must be OFF Shadow loop lead in wires are twisted approx. 6 twists per foot series Shadow Loop Output Com N.O Note: Relay 21 (Red) MotorMotor 1 (Red) (Blue) Motor Motor 2 (Blue) (White) Neutral Neutral 3 (White) (Yellow) Limit Limit 5 (Yellow) (Brown) Spare Spare 6 (Brown) (Orange) Limit Limit 7 (Orange) (Gray) COM COM 8 (Gray) 22 LOW VOLTAGE COMMONRADIO RELAY (SINGLE BUTTON) ACTIVATION (250 ma. maximum) OPEN LOOP LOGIC OUTPUT 7.GATE TRACKER DATA 8.GATE TRACKER BUSY 9.MAGNETIC LOCK OUTPUT 10.DRY RELAY CONTACT 11.DRY RELAY CONTACT 12.LOW VOLTAGE COMMON 13.LOW VOLTAGE COMMON 14.ALARM 15.ALARM RESET 17.MOTOR 18.MOTOR10 19.115 VAC HOT 20.115 VAC NEUTRAL 23 2.CLOSE DIRECTION NON-CONTACTSENSOR (Photocell)3.Not used 4.Not used 5.COMMON 6.COMMON Spare COM Interconnection Cable 1 Motor (Red) 2 Motor (Blue) 3 Neutral (White) 4 24VAC (Purple) 5 Limit (Yellow) 6 Spare (Brown) 7 Limit (Orange) 8 COM (Gray) 24 shut-offand then turned back on for the new setting to take effect DIP-Switches Auto Close Timer • Auto close timer (when turned on) SW 1, switch Adjust from second (full to approximately 23 seconds (full clockwise) Self Test The operator will gate to function Reverse Sensor Dry Relay Contact respectively 25 SW 1 (Top 8 Switches)Function Setting Description Terminal 4 is the output from the open detector Terminal 4 is an open input Auto-closetimer is OFF. Manual input required to close gate Timer Auto=close timer is ON. Adjustable from 1-23seconds Terminal 6 is a Reverse input Terminal 6 is a Shadow input Switch must be OFF for single operator Switch must be ON when bi-parting(dual) gates are used Relay activates when gate is open 7-OFF 8-ON Relay activates when gate is not closed 7-ON Relay activates when gate is opening and open 8-ON Relay activates when gate is opening and closing Switch SW 2 (Bottom 4 Switches) Primary and secondary operators start at the same time Secondary operator starts 1-2seconds prior to the primary operator Magnetic lock is not used Magnetic lock is used and connected to terminals 9 and Switch 4 Spare switch, not used. Leave in OFF position 26 The hub must not slip during operationTighten bolt to stop any slipping Magnetic Sensor Activator Magnetic sensor activator must be directly above the limit sensors to activate them limit sensors to the open and closed positions of the operator arm Magnetic Close Magnetic Open Limit Sensor A secondary entrapment protection device must be installed with this operator Photo Cells 27 IMPORTANT SAFETY INSTRUCTIONSWARNING NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE 8.SAVE THESE INSTRUCTIONS Reset Switch Alarm Speaker DC Power Switch 28 softhard (alarm) Soft Shutdown will not Example Resetting a Soft Shutdown Hard Shutdown 29 Resetting a Hard ShutdownNEVER Emergency Vehicle Access Conditions In the event of a primary (AC) power failure and a 30 Manual Release31 The convenience open system uses two•Batteries are not covered under warranty Automatic Open after loss of AC Power communities, apartment complexes, etc Switch 1 OFF is not used DIP-Switches Restart Options once AC Power is restored 32 Do Not AdjustTimer Not Used Do Not Adjust DC Motor To Primary or Single Operator Function Gate will automatically open when a power outage occurs Set so that the gate cycles to the open direction upon loss of AC power required to return the gate to normal operation automatically restore normal operation Must be in the ON position 33 When servicing this gate operator, always turn power OFFOperator Monthly Interval Component Alarm entrapment alarm should activate. Press the reset button to silence the alarm Arms Check set screws and nuts. Check bushings for wear Batteries be replaced every two years DC Open System be sure the system opens the gate upon loss of AC power Drive Belt Check for alignment, tightness and wear Fire Dept Gate necessary Primary Reverse System the opening and closing cycles Adjust the reversing sensor if necessary Loop(s) Release Check manual release for proper operation gate when activated Complete System Complete check of gate and gate operating system 34 SymptomPossible Solution(s) • Check that power to the operator is turned ON Power LED is OFF retest. Check for low 115 VAC power and low voltage shorts replace the circuit board Power LED is ON to next steps 14 AWG insulated jumper wire. CAUTION – HIGH VOLTAGE. The motor should run the above step from the control board to the motor or a bad control board Secondary operator • Check that SW-1,switch 6 is ON motor will not run to each terminal operator, bad secondary motor or motor capacitor 35 Check ERD setting• Make sure operator hub does not slip when gate encounters an obstruction is encountered • Check the reversing sensitivity and reverses binding • Replace the circuit board not close with the safety device loop detector or ground loop to normal operation • If automatic close is desired, be sure SW-1,switch 4 is ON • Check motor as described on previous page not open then re-connectthe wire going to the respective terminal. Operator should open above section if operator now opens but will not close keying device. If LED does not light, replace control board • Check that the reverse sensitivity is properly adjusted then reverses to open gate to reverse • Check for any input or loop detector LEDs that are ON re-opens Alarm sounds for minutes and then normal operation seconds. Operator will not run • Check that the DC system power switch is in the ON position AC power outage Check the batteries for proper voltage. Replace if necessary • Replace the DC system circuit board 36 Constant tone is heard when power is applied:Constant tone is heard: MMTC, Inc. Model IR55 MMTC, Inc. Model Carlo Gavazzi Type PMP12 Carlo Gavazzi Type PMT Loop Detector P/N 9409-010– Two-channeldetector P/N 1216-080and P/N Remote Reset P/N Control Station Interconnect Cable Time Clock Torsion Rods Hinges Surge Devices P/N 1876-010- High Voltage P/N 1878-010- Low Voltage Gate Scale - Use to test torque required to move gate. P/N Speed Bumps 37 Sensor50uf Capacitor Push to Operate Alarm 115 VAC Reset Current 38 BatteriesDC Power 41 1 HP
Also you can find more DKS Enterprises manuals or manuals for other Baby.