SPECIFICATIONS

Class of Operation

 

 

Model 6500 - UL325 Class I, II, III, IV

Type of Gate

 

 

 

 

 

 

Vehicular Swing Gates Only

 

 

 

 

 

 

Horsepower

 

 

 

 

 

 

1/2 or 1 HP

 

 

 

 

 

 

Voltage / Phase

 

 

 

 

 

115 VAC Single-Phase, 230 VAC Single-Phase, 460 VAC Single-Phase

 

 

 

 

 

Current

 

 

 

 

 

½ HP – 5.4 Amps @ 120V; 2.7 Amps @ 230V; 1.35 Amps @ 460V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 HP – 9.7 Amps @ 120V; 4.9 Amps @ 230V; 2.5 Amps @ 460V

Max Gate Weight

 

 

1/2 HP - 600 Lbs.; 1 HP - 800 Lbs.

Max Gate Length

 

 

1/2 HP - 18 Ft.; 1 HP - 22 Ft.

Cycles Per Hour

 

 

60 Per Hour

Speed

 

 

90° in approximately 12-14 seconds

Entrapment Protection

 

Primary - Inherent entrapment sensing system (Type A)

 

 

 

 

 

 

 

 

 

 

 

Secondary - Provision for connection of a non-contact sensor (Type B1)

This manual is for 6500 operators manufactured after July 12, 2008.31 5/8

 

31”

 

28 3/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18 3/8

 

 

 

 

23 1/4

 

 

 

 

 

 

 

 

Use this manual with the following models only:

6500-080, 6500-081, 6500-082*, 6500-083*, 6500-084, 6500-085, 6500-086*, 6500-087*, 6500-088, 6500-089*, 6500-090, 6500-091*, 6500-092, 6500-093*, 6500-094, 6500-095*, 6500-096, 6500-097*, 6500-098, 6500-099*.

*Optional Convenience Open System

DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.