Vehicular Swing Gate Operator
Page
Model 6500 - UL325 Class I, II, III
Vehicular Swing Gates Only
1/2 or 1 HP
1/2 HP - 600 Lbs.; 1 HP - 800 Lbs
1/2 HP - 18 Ft.; 1 HP - 22 Ft
Glossary
Auxiliary Device Wiring
Page
www.astm.org
WARNING - To reduce the risk of injury or death:
1.READ AND FOLLOW ALL INSTRUCTIONS
Always keep people and objects away from gate
5.Use the emergency release only when the gate is not moving
•For gate operators utilizing contact sensors:
•Pinch points
•Entrapment areas
•Reach through hazards
•Absence of entrapment protection devices
Class
Class
UL325
Horizontal Slide, Vertical Lift, Vertical Pivot
Swing and Vertical Barrier (arm)
Classifications
Class
A- Inherent entrapment protection system
C- Inherent adjustable clutch or pressure relief device
E- An inherent audio alarm
GATE
RESIDENTIAL VEHICULAR GATE OPERATOR – CLASS
multi-family
VEHICULAR BARRIER (ARM) OPERATOR (OR SYSTEM)
VEHICULAR
(ref. UL325 56.8.4.b)
Closed Gates
Closed Gate
If space is less than 16 inches
entrapment protection in this area
Non-contactSensor
Reverse Loop
Minimizes the potential
Minimizes the potential of the gate
of the gate closing on
Primary
Secondary
Position
Primary/Secondary Interconnection Cable (Dual Operator Application Only)
Low Voltage Control and/or P.A.M.S. Wires
90°
22”
Concrete Pad Location
Operator Installation
29.5”
Operator Installation
Operator Installation
ARelease hub with release tool. DO NOT REMOVE HUB
BBolt crank arm to operator
CSlide elbow assembly on crank arm
DBolt control arm to gate bracket
Slide control arm into elbow assembly. KEEP ARM ASSEMBLY LEVEL
Page
This table illustrates the high voltage wire size and distance requirements
Model
Voltage
Amps
Wire Size / Distance in Feet
dependent on the specific installation requirements
be provided by non-contactor contact sensors, or a
Open direction non-contactsensor
combination of both
Secondary device wiring shows inputs to the circuit
Loop detector wiring is shown for DoorKing
Loop layout shown is for a typical swing gate application with
www.dkaccess.com
Note: SW 1
switches 5
Page
(Red) Motor
Motor 1 (Red)
(Blue) Motor
Motor 2 (Blue)
(White) Neutral
LOW VOLTAGE COMMON
RADIO RELAY (SINGLE BUTTON)
ACTIVATION
(250 ma. maximum)
OPEN LOOP LOGIC OUTPUT
2.CLOSE DIRECTION NON-CONTACTSENSOR (Photocell)
3.Not used
4.Not used
5.COMMON
6.COMMON
shut-off
and then turned back on for the new setting to take effect
DIP-Switches
Auto Close Timer
• Auto close timer
SW 1 (Top 8 Switches)
Function
Setting
Description
Terminal 4 is the output from the open detector
The hub must not slip during operation
Tighten bolt to stop any slipping
Magnetic Sensor Activator
Magnetic sensor activator
must be directly above the
IMPORTANT SAFETY INSTRUCTIONS
WARNING
NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE
8.SAVE THESE INSTRUCTIONS
Reset Switch
soft
hard (alarm)
Soft Shutdown
will not
Example
Resetting a Hard Shutdown
NEVER
Emergency Vehicle Access Conditions
In the event of a primary (AC) power failure and a
Manual Release
The convenience open system uses two
•Batteries are not covered under warranty
Automatic Open after loss of AC Power
communities, apartment complexes, etc
Switch 1 OFF is not used
Do Not Adjust
Timer Not Used Do Not Adjust
DC Motor
To Primary or Single Operator
Function
When servicing this gate operator, always turn power OFF
Operator
Monthly Interval
Component
Alarm
Symptom
Possible Solution(s)
• Check that power to the operator is turned ON
Power LED is OFF
retest. Check for low 115 VAC power and low voltage shorts
Check ERD setting
• Make sure operator hub does not slip when gate encounters an obstruction
is encountered
• Check the reversing sensitivity
and reverses
Constant tone is heard when power is applied:
Constant tone is heard:
MMTC, Inc. Model IR55
MMTC, Inc. Model
Carlo Gavazzi Type PMP12
Sensor
50uf Capacitor
Push to Operate
Alarm
115 VAC
Batteries
DC Power
Page
Page
1 HP