5.2 DC System Description

Do Not Adjust

Batteries

 

 

– +

 

Red/White

 

 

 

 

 

 

12 V Amp/Hr

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 V 3 Amp/Hr +

DC ON/OFF

Power Switch

Black/White

Timer Not Used Do Not Adjust

Charging LED

2340

DIP-Switches

Red/White

OUTPUT NEGATIVE MOTOR DC OUTPUT POSITIVE MOTOR DC INPUT NEGATIVE BATTERY INPUT POSITIVE BATTERY COMMON VAC 24 INPUT VAC 24 OUTPUT ACTIVATION .used Not POWER RADIO INPUT OPEN .used Not COMMON

Gate will automatically OPEN and stay open during an AC power failure. DIP-Switch 3 setting will determine how operator will return to normal operation once AC power has been restored.

DC Motor

Black

Red

 

To Primary or Single Operator

To Secondary Operator

 

 

 

Orange to P2 Plug on Circuit Board

Orange to Second Terminal #5

 

Diode

 

 

 

 

White to Main Terminal #13

White to Second Terminal #7

 

 

 

Purple to Main Terminal #3

Purple to Second Terminal #8

 

 

 

Green to Main Terminal #5

Green not used.

5.3 DIP-Switch Settings

Switch

Function

Setting

Description

1

Operation

OFF

Not Used

ON

Gate will automatically open when a power outage occurs.

 

 

 

 

 

 

 

2

Changes

OFF

Set so that the gate cycles to the open direction upon loss of AC power.

Open Direction

 

 

 

 

Automatic

OFF

When AC power is restored, an input (push button, loop, radio receiver, etc.) is

 

required to return the gate to normal operation.

3

Power-up

 

ON

When AC power is restored, a 1-second pulse is sent to the gate operator input to

 

Activation

 

automatically restore normal operation.

 

 

 

 

 

 

 

4

Operator Type

ON

Must be in the ON position.

5

Not Used

OFF

 

6

Not Used

OFF

 

7

Not Used

OFF

 

8

Not Used

OFF

 

30

6500-065-K-7-08