Honeywell 5690/5693 manuals
Marine Equipment > Marine Radio
When we buy new device such as Honeywell 5690/5693 we often through away most of the documentation but the warranty.
Very often issues with Honeywell 5690/5693 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Marine Radio Honeywell 5690/5693 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Marine Radio on our side using links below.
Honeywell 5690/5693 Manual
190 pages 3.03 Mb
3 UL Statement (Recognized component)D-MarkStatement LED Safety Statement CB Scheme Laser Safety Statement 5 Table of ContentsChapter 1 - Getting StartedIntroduction About This Manual Unpacking Your Device OEM Engine Models Chapter 2 - Programming the InterfaceKeyboard Country Layout Keyboard Conversion Control Character Output Keyboard Modifiers RS232 Modifiers RS232 Baud Rate RS232 Word Length: Data Bits, Stop Bits, and Parity RS232 Receiver Time-Out RS232 Handshaking RS232 Timeout ACK/NAK 6 Chapter 3 - Input/Output SettingsOutput Sequence Editor To Add an Output Sequence Partial Sequence Require Output Sequence Multiple Symbols No Read Video Reverse 7 Chapter 4 - Data EditingPrefix/Suffix Overview Suffix Selections Intercharacter Delay Chapter 5 - Data FormattingData Format Editor Introduction Add a Data Format Terminal ID Table Data Formatter Data Format Non-MatchError Tone Primary/Alternate Data Formats Single Scan Data Format Change Chapter 6 - Symbologies 9 Chapter 7 - Imaging CommandsChapter 8 - Interface Keys Chapter 9 - Utilities Chapter 10 - Serial Programming Commands 10 Chapter 11 - MaintenanceChapter 12 - Customer Support Appendix A - Reference Charts 11 Getting Started17 Programming the Interface18 USB IBM SurePosUSB PC or Macintosh Keyboard USB HID 19 CTS/RTS EmulationACK/NAK Mode 20 Gilbarco® Terminal Default SettingsHoneywell Bioptic Aux Port Configuration Datalogic™ Magellan® Aux Port Configuration NCR Bioptic Aux Port Configuration 21 Wincor Nixdorf Terminal Default SettingsWincor Nixdorf Beetle™ Terminal Default Settings Keyboard Countries 22 Keyboard Countries (Continued)32 RS232 Baud Rate33 RS232 Word Length: Data Bits, Stop Bits, and ParityData Bits Stop Bits Parity 8 Data, 1 Stop, Parity Even * 8 Data, 1 Stop, Parity None 8 Data, 1 Stop, Parity Odd 8 Data, 1 Stop, Parity Mark 34 RS232 Receiver Time-OutRS232 HandshakingFlow Control, No Timeout: Two-Direction Flow Control: Flow Control with Timeout: Flow Control, No Timeout Two-DirectionFlow Control Flow Control with Timeout * RTS/CTS Off 35 RS232 TimeoutXON/XOFFXON/XOFF On XON/XOFF Off * XON/XOFF Off ACK/NAKACK/NAK On ACK/NAK Off * ACK/NAK Off 36 RS232 Stop ModeScanner-BiopticPacket ModePacket Mode On * Packet Mode Off Packet Mode On Scanner-BiopticACK/NAK ModeBioptic ACK/Nak On * Bioptic ACK/NAK Off Bioptic ACK/NAK On 37 Scanner-BiopticACK/NAK Timeout39 Input/Output Settings40 Beeper – Good ReadOff Beeper - Good Read Off * Beeper - Good Read On Beeper Volume – Good Read Beeper Pitch – Good ReadLow (1600 Hz) * Medium (2700 Hz) 41 Beeper Pitch – ErrorBeeper Duration – Good Read LED – Good Read 42 Number of Beeps – Good ReadNumber of Beeps – Error Good Read Delay User-SpecifiedGood Read DelayNormal Enhanced * Manual Trigger - Normal Manual Trigger - Enhanced 43 Read Time-OutRead Time-Out Read Time-Out Presentation Mode 44 LED Illumination - Presentation ModePresentation LED Behavior after Decode Presentation SensitivitySensitivity 45 Streaming Presentation Mode- Normal - Enhanced Hand Held Scanning - Mobile Phone Streaming Presentation Mobile Phone Image Snap and Ship Image Snap and Ship Hands Free Time-Out Hands Free Time-Out Short (500 ms) * Medium (750 ms) Long (1000 ms) Extra Long (2000 ms) 46 User-SpecifiedReread DelayUser-SpecifiedReread Delay 47 2D Reread Delay2D Reread Delay Off * 2D Reread Delay Off Short (1000ms) Medium (2000ms) Long (3000ms) Extra Long (4000ms) Lights On Lights Off * Lights On Lights Off 200 milliseconds 400 milliseconds *Off (no delay) 48 User-SpecifiedAimer DelayDelay Duration * Interlaced Centering On Top of Centering Window, Bottom of Centering Window, Left Right of Centering Window 49 Centering On* Centering Off Top of Centering Window Bottom of Centering Window high priority low priority unspecified type Preferred Symbology On * Preferred Symbology Off 50 High Priority SymbologyLow Priority Symbology 51 Preferred Symbology Time-outPreferred Symbology Default To Add an Output SequenceEnter Sequence 2.Code I.D 3.Length 4.Character Match Sequences 5.End Output Sequence Editor F F Other Programming Selections 52 Output Sequence ExampleSEQBLK62001241FF6A001342FF69001243FF 53 Partial SequenceDiscard Partial Sequence Transmit Partial Sequence * Discard Partial Sequence Require Output SequenceRequired On/Not Required 54 *Off* Off Video Reverse Off Video Reverse Only Video Reverse and Standard Bar Codes Video Reverse Only Video Reverse Off Video Reverse and Standard Bar Codes Video Reverse Only 57 Data Editing63 Data Formatting77 Symbologies127 Imaging Commands141 Interface Keys145 Utilities149 Serial Programming Commands171 Maintenance173 Customer Support175 Reference Charts
Also you can find more Honeywell manuals or manuals for other Marine Equipment.