Thomas & Betts BE manuals
Lawn and Garden > Patio Heater
When we buy new device such as Thomas & Betts BE we often through away most of the documentation but the warranty.
Very often issues with Thomas & Betts BE begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Patio Heater Thomas & Betts BE is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Patio Heater on our side using links below.
Thomas & Betts BE Warranty
28 pages 2.13 Mb
GENERAL Model FE and BE 2 1. Installation CodesSpecial Installations (Aircraft Hangars/ Garages) WARRANTY: Warranty is void if...... HAZARD INTENSITY LEVELS 1. DANGER: 2. WARNING: 3. CAUTION: 2. Warranty 3 3. DimensionsFan-Type, Power-Vented Unit Heater Dimensions (mm) Dimensions (inches) 4 3. Dimensions (cont'd)Blower-Type, Power-Vented Unit Heater Dimensions (inches) Dimensions (mm)GH J K L Hange r GH J K L Hanger XYZ Hanger 5 4. Uncrating and Preparation5. Unit Heater LocationCAUTION: Do not locate the heater where it may be exposed to water spray, rain or dripping water. 6. Clearances & Combustion Air 6 7. Combustion Air Requirements for a Heater Located in a Confined Space6. Clearances and Combustion Air (cont'd) 8. Suspending the HeaterFigure 4A - Four-Point Suspension with Swivel Connections (Applies to both fan and blower models) Figure 4B - Suspension Dimensions (inches and mm) for Model BE Heater with Hanger Kit Option CK19 Figure 3 - Two- Point Suspension with Swivel Connections (fan models only) Optional, Field-Installed Hanger Kits: 7 9. VentingSpecific Venting Requirements (read all before 1. Venter (Flue) Outlet Venter Outlet Size: 8 9. Venting (cont'd)Venter Outlet Attachment Requirements: 2. Vent Pipe 2A. Vent Pipe Diameter Reduction 3. Vent Length Tables 4. Vent System Joints 5. Vent System Support 6. Condensation 7. Vent Terminal (Pipe and Vent Cap) 10 10. Gas Piping and PressuresInstructions to Check Manifold Pressure: 11 11. Electrical Supply and Connections12. Thermostat and Thermostat Connections 12 TYPICAL WIRING DIAGRAMS -- Pages 12 - 15Fan-Type, Power-Vented Model with Intermittent Spark Pilot, Single-Stage Heating, Natural or Propane 16 13. Fan Motor14. Blower Motor 12. Thermostat Connections (cont'd)Figure 12 - Wiring Diagrams for Optional Controls Figure 13 - Adjusting Belt Tension 17 15. Blower Speed AdjustmentBlower Model Sizes 25-100 with Direct Drive 16. Blower Rotation 17. Fan ControlWARNING: If you turn off the power supply, turn off the gas. See Hazard Levels, page 2. 18. Limit ControlBlower Model Sizes 50-400 with Belt DriveFigure 14 - Air Shutter Adjustment Screws -- Alternate Turning Screws When Adjusting Shutter 18 19. Combustion Air Proving Switch20. Gas Valve 21. Pilot and Ignition System 22. Burners 23. Burner Air Adjustment 19 24. Check Installation and Start-Up20 27. Optional Duct Flange - Option CD9 (Blower Models only)OPTIONAL EQUIPMENT 25. Optional Vertical Louvers - Option CD1 26. Optional Downturn Air Nozzles - Figure 15 - Optional Vertical Louvers Sizes "A" Range of Air Deflection Figure 16 - Optional Downturn Nozzles Sizes "A" Range of Air Deflection 21 28. Optional Polytube Adapter - Options CD6, CD8, and CD11 (Blower Models only)Figure 17 - Polytube Adapter 75 925 18 110 100 1235 18 145 125 1540 18 185 130 1600 24 190 165 2035 24 240 200 2465 24 300 250 3085 24 360 300 3700 24 425 400 4935 24 550 22 29. Optional Guards - Options CD10 & CD12 (Blower Models only)30. Optional Multiple Heater Control - Options CL31 & CL32 31. Optional Blower/Filter Cabinet - Options CW1, CW2, or CW3 (Blower Models Only) 23 SERVICE AND MAINTENANCE32. Burner Rack RemovalInstructions for Burner Rack Removal (See Figures 21-24.) WARNING: If you turn off the power supply, turn off the gas. See Hazard Levels, page 2. CAUTION: Eye protection is recommended. 24 33. Pilot and Ignition System32. Burner Rack Removal 25 36. Heat Exchanger37. Fan or BlowerCAUTION: Eye protection is recommended. 35. Flash Carryover 34. Burner Orifices 26 37. Fan (cont'd)38. Venter Motor 39. Operating Gas Valve 40. Fan and Limit ControlsInstructions for replacing fan or limit control: 41. Vent SystemMfg P/N 98807 Rev 8, Page 27 27 42. Troubleshooting28 FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER:
Also you can find more Thomas & Betts manuals or manuals for other Lawn and Garden.