Trane YCZ036F1/3M0B manuals
Kitchen Appliance > Ventilation Hood
When we buy new device such as Trane YCZ036F1/3M0B we often through away most of the documentation but the warranty.
Very often issues with Trane YCZ036F1/3M0B begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Ventilation Hood Trane YCZ036F1/3M0B is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Ventilation Hood on our side using links below.
Trane YCZ036F1/3M0B Manual
24 pages 1.48 Mb
2002 American Standard Inc. All rights reserved HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING WARNING: INSTALLATION OPERATION MAINTENANCEALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Single Package Two Stage Gas/Electric 16 SEER Convertible 3, 4, 5 TonModel: YCZ036F1/3M0B, 4MOA YCZ050F1/3HOA, 4H0A YCZ060F1/3M0B, 4M0ABAYLIFT002A LIFTING LUG KIT 18-EB21D4-7 YCZ-IOM-1FPage 2 GENERAL INFORMATIONIMPORTANT: Read this entire manual before beginning installation procedures. and where property-damage-only accidents could occur. result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could 2 NOTICEWarnings and Cautions appear at appropriate locations throughout this manual. Read these carefully. 4 3YCZ036,050,060F OUTLINE BACK11 w" PVC OR COPPER 1-1/2" / TUBING AND FITTINGSTYPICAL GROUND LEVEL APPLICATION (YCZ036,050,060F MODELS) qPage 12 ATTACHING HORIZONTAL DUCTWORK TO UNIT DUCTWORKATTACHING DOWNFLOW DUCTWORK TO ROOF CURB HORIZONTAL 12 DOWNFLOWPage 13 PIPE DELIVERY SCHEDULE 13 rTABLE 1 GAS PIPING INSTALLATIONTABLE 2GAS PRESSURE SETUP PRECAUTIONS GAS SUPPLY LINE PRESSURE.50 1.10 .55 1.04 .60 1.00 .65 .962 SCHEMATIC DIAGRAM OF GAS PIPING TO UNIT 14 yGAS PIPING INSTALLATIONBURNER & VALVE ILLUSTRATION FLUE AND HOOD ILLUSTRATION tPage 15 GAS PIPING INSTALLATION 15 uHIGH ALTITUDE INSTALLATION * Switch Toggles "ON" or "OFF" 16 ELECTRICAL WIRINGPage 16 ELECTRICAL CONNECTIONS ELECTRICAL POWER DISCONNECT SWITCH OVER CURRENT PROTECTION POWER WIRING FILTER INSTALLATIONSq.Ft.- SIZE FILTER AIR FILTERS TABLE 4THERMOSTAT HEAT ANTICIPATOR CONTROL WIRING (CLASS II)WIRE SIZE MAXIMUM LENTGH (Ft) 18 75 16 125 14 200 TABLE 5UNIT NOMINAL CFM FILTER* RESISTANCE YCZ036F 1200 4 0.05 YCZ050F 1600 5.33 0.05 YCZ060F 2000 6.67 0.05 ELECTRICAL WIRING 17 iPage 18 18 START - UPPRE-START QUICK CHECKLIST STARTING THE UNIT IN THE COOLING MODE OPERATING PRESSURES VOLTAGE COOLING SHUT DOWN HEATING CYCLE Page 19 19 START - UPSTARTING THE UNIT IN THE GAS HEATING MODE MANIFOLD PRESSURE SEQUENCE OF OPERATION 20 oDIP SWITCHES (TYPICAL SETTINGS) SEQUENCE OF OPERATIONICM FAN CONTROL TROUBLESHOOTING CHART CHECKOUT PROCEDURE 21 pIGN LED DIAGNOSTIC INDICATOR MAINTENANCE 22
Also you can find more Trane manuals or manuals for other Kitchen Appliance.