Trane YCZ036F1/3M0B, YCZ035F1 Checkout Procedure, Ign Led Diagnostic Indicator, System Faults

Models: YCZ036F1/3M0B YCZ035F1

1 24
Download 24 pages 41.31 Kb
Page 21
Image 21
IGN LED DIAGNOSTIC INDICATOR

 

IGN LED DIAGNOSTIC INDICATOR

 

 

FLASHING SLOW

NORMAL CALL FOR HEAT

 

 

CONTINUOUS ON

NORMAL

 

 

CONTINUOUS OFF

CHECK POWER / INTERNAL FAILURE

 

 

2 FLASHES

SYSTEM LOCKOUT ( NO FLAME )

 

 

3 FLASHES

PRESSURE SWITCH PROBLEM

 

 

4 FLASHES

HIGH LIMIT (TCO) OPEN

 

 

5 FLASHES

FLAME SENSED WITH GAS VALVE OFF

 

 

6 FLASHES

FLAME ROLLOUT SWITCH (FL) OPEN

 

 

7 FLASHES

W1 & W2 SWAPPED

 

 

p

CHECKOUT PROCEDURE

TROUBLESHOOTING CHART

SYSTEM FAULTS

REFRIGERANT CIRCUIT

Liquid Pressure Too high

Liquid Pressure Too Low

Suction Pressure Too High

Suction Pressure Too Low

Liquid Refrigerant floodback (TXV System) Liquid Refrig. floodback (Cap. Tube System)

I. D. Coil Frosting

Compressor Runs Inadequate or No Cooling

ELECTRICAL

Compressor & O.D. fan Do Not Start Compressor Will Not Start But O.D. Fan Runs O.D. Fan Won't Start

Compressor Hums But Will Not Start

Compressor Cycles on IOL

I.D. Blower Won't Start

P-PRIMARY CAUSES S-SECONDARY CAUSES

Page 21

Page 21
Image 21
Trane YCZ036F1/3M0B, YCZ035F1 manual Checkout Procedure, Ign Led Diagnostic Indicator, System Faults, Troubleshooting Chart