Unisys NX5820 manuals
Computer Equipment > Server
When we buy new device such as Unisys NX5820 we often through away most of the documentation but the warranty.
Very often issues with Unisys NX5820 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Server Unisys NX5820 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Server on our side using links below.
176 pages 1.07 Mb
Product Information Announcement 5 Unisys7 ClearPath HMP Enterprise ServersNX5820 and NX5820 KHardware Configuration Guide 9 Contents13 Figures15 Tables17 About This Guide21 Section 1 Introduction How to Use This GuideWhat Product Models Are Covered 22 What Product Models Are CoveredSystem ArchitectureFeatures Technology Enhancements 23 System PartitioningSingle Domain Dual DomainSingle Monolithic Partition Two Separate Partitions Hardware Overview 24 Hardware OverviewType of Computing System The System CabinetCentral Equipment Complex (CEC) Section Hardware Overview Expansion Sections SVGA Monitor and Keyboard with Mouse 25 The I/O SubsystemRack-Mounted Devices System Cabinet Organization Other I/O Devices 26 System Cabinet OrganizationSupported Peripherals System Components27 7017 6300005 17Table 12. Acronyms for System Components 7017 6300005 19 Front ViewFigure 12. System Cabinet PCA Locations for NX5820 Rear ViewImpeller Impeller Domain 0 Domain 1 Impeller Impeller Domain 1 Domain 0 AC Inlet AC Inlet Redundant Cooling AC Inlet Power C o m m o n I / O Operator Panel Inlet Redundant A06 A05 A03 A01 A04 ** 29 *Can not be used for CS-Bus connectivity110 7017 6300005Front View Can not be used for CS-Bus connectivity Rear ViewImpeller Impeller Domain 0 Domain 1 Impeller Impeller Domain 1 Domain 0 AC Inlet AC Inlet Redundant Cooling AC Inlet Power C o m m o n I / O Operator Panel Inlet Redundant A06 A05 A03 A01 A04 ** 30 ** *Figure 13. System Cabinet PCA Locations for NX5820 KMAINTLAN FEEDTHRU MCP Environment Domain 0 NTPCI Bridge 10 BaseT CS Bus SCP10 BaseT CSE Maintenance LAN HubST Switch POWERNET APC Remote Support T27's System TerminalDISK Ch TAPE Ch Public Switch Tape Disk OSS7000 31 7017 6300005 11132 112 7017 6300005 33 Section 2 Configuring System Hardware NX5820 ProductsSingle-Domain, Single-Processor (SDSP) NX5821 Models 31 to 71 Dual-Domain, Multiple-Processor (DDMP) NX5822 Models 32 to 7834 NX5820 Products227017 6300005 NX5820 Single-Domain, Single-Processor (SDSP) Models NX5820 Dual-Domain, Multi-Processor (DDMP) Models 35 NX5820 Product Configurations36 247017 630000537 7017 6300005 25Figure 21. NX5820 Single-Domain System Cabinet Configuration with VX1305 Servers 39 7017 6300005 27Table 23. ClearPath Enterprise Server NX5822 Dual-Domain, Multi-Processor Models 32 through 72 40 287017 6300005Table 23. ClearPath Enterprise Server NX5822 Dual-Domain, Multi-Processor Models 32 through 72 Table 24. ClearPath Enterprise Server NX5822 Dual-Domain, Multi-Processors Models 73 through 78 41 7017 6300005 29Table 24. ClearPath Enterprise Server NX5822 Dual-Domain, Multi-Processors Models 73 through 78 42 210 7017 6300005Figure 24. NX5820 Dual-Domain System Cabinet Configuration, with VX1505 Servers Figure 23. NX5820 Dual-Domain Redundant System Cabinet Configuration, with VX1305 ServersCEC (Primary) (Redundant) OSS7000 Peripheral Rack APC2 APC2 APC2 7017 6300005 211 43 NX5820 Companion Package Style44 NX5820 K ProductsSingle-Domain, Single-Processor (SDSP) NX5821 BAS Models Dual-Domain, Dual Processor (DDDP) NX5822 BAS Models 45 Dual-Domain, Multiple-Processor (DDMP) NX5822 BAS Models46 214 7017 6300005Table 26. ClearPath Enterprise Server NX5820 K Product ModelsNX5820 K Single-Domain, Single-Processor (SDSP) Models NX5820 K Dual-Domain, Dual-Processor (DDDP) Models NX5820 K Dual-Domain, Multi-Processor (DDMP) Models 7017 6300005 215 Table 26. ClearPath Enterprise Server NX5820 K Product Models 47 NX5820 K Product Configurations57 CablesPower Layout and Requirements Redundant Power/Cooling 58 NX5820 System Upgrades59 NX5820 System UpgradesSingle Processor Figure 210. NX5820 Upgrade Diagram 7017 6300005 227System Package Style Upgrade Package Style Single Doma in Multi Processor Dual Domain 60 NX5820 System Upgrades228 7017 6300005 Table 211. NX5820 Single Domain, Single Processor Model Upgrades (SDSP to SDSP) Components required for all above package styles 7017 6300005 229 Table 213. NX5820 Dual Domain Multi Processor Upgrades (DDMP to DDMP) 61 NX5820 K System Upgrades62 230 7017 6300005Figure 211. NX5820 K Upgrade DiagramUpgrade Package Style Single Domain Single Processor Dual Domain Dual Processor Upgrade Package Style System Package Style Dual Domain Multi Processor 63 7017 6300005 231Table 214. NX5820 K Upgrade Options Summary Table 215. Performance Upgrades for Single-Domain, Single-Processor Systems 64 232 7017 630000567 Section 3 Configuring System Options 83 Section 4 Configuring I/O Cabinets and Channel Racks 89 Section 5 Configuring the Input/Output Module Introduction 90 How the IOM Is OrganizedIOM Logical Organization 91 IOM Physical Organization92 547017 6300005Figure 53. Card Module Assembly for NX5820 * Front View Rear View 7017 6300005 55 Front View Rear View *The first CIOM board in the domain goes into this slot.Domain 0 Domain 1 Cooling Module Operator Panel AC Inlet AC Inlet ** k Air Inlet Air Inlet L o g i R a Cooling Module Power Module Power Module L o g i R a Domain 0Domain 1 ** Operator Panel **Optionally dedicated for Multi-IOU functionality Optionally dedicated for TCU functionality ***Figure 54. Card Module Assembly for NX5820 K 93 IOM Options CMF external connectivity options CIOM upgrade CMF External Connectivity 94 CIOM Upgrade95 Configuring Channels103 PCITHRU Feature CardPCI3-FTH CA626-BAS CS-3 CS-3 P1 P2 M I T L Domain 1 Domain 0B8 BT B7 B6 B5 B0 AT A4 A3 A2 A1 A0 D8 DT D7 D6 D5 D0 CT C4 C3 C2 C1 C0 Remote Channel Rack To Server D's Terminator Jumper CSB3-20C Cable Assembly Feedthru To Server B's To Server C's PCI3-FTH To Server A's Figure 58. Dual Domain Typical PCITHRU Card Location in the Internal and External Channel Racks 104 PCITHRU Feature CardConfiguring QIC Tape and CD-ROM 105 Configuring QIC Tape and CD-ROMInformation Contained in the NX Systems I/O Configuration Guide 107 Section 6 Configuring the Servers 108 VX1305 Servers116 VX1505 Servers125 ES5085R Servers128 622 7017 6300005550 MHZ, 512K CacheXEO3550-512 Figure 65. Road Map for Ordering ES5085R ServersDIM6168-128 DIM6168-256 DIM6168-512 1X128 MB DIMM 1X256 MB DIMM 1X512 MB DIMM XEO3550-1MB XEO3550-2MB 550 MHZ, 1MB Cache 550 MHZ, 2MB Cache XEO3550-1MB XEO3550-2MB 550 MHZ, 1MB Cache 550 MHZ, 2MB Cache 550 MHZ, 512K CacheXEO3550-512 DIM6168-128 DIM6168-256 DIM6168-512 1X128 MB DIMM 1X256 MB DIMM 1X512 MB DIMM 131 Configuration Guidelines ES5085R132 ES2024R Servers139 ES5044R Servers142 636 7017 6300005700 MHZ, 1MB CacheXEO37001-1MB Figure 69. Road Map for Ordering ES5044R ServersDIM10068-64 DIM10068-128 DIM10068-256 DIM10068-512 1X64 MB DIMM 1X128 MB DIMM 1X256 MB DIMM 1X512 MB DIMM XEO37001-2MB XEO38001-2MB 700 MHZ, 2MB Cache 800 MHZ, 2MB Cache 700 MHZ, 1MB CacheXEO37001-1MB XEO37001-2MB XEO38001-2MB 700 MHZ, 2MB Cache 800 MHZ, 2MB Cache DIM10068-64 DIM10068-128 DIM10068-256 DIM10068-512 1X64 MB DIMM 1X128 MB DIMM 1X256 MB DIMM 1X512 MB DIMM 145 Configuration Guidelines ES5044R146 Configuring the Private Maintenance Hub and Public Switching LAN156 Configuring Optional and Recommended UPS157 7017 6300005 651Table 635. UPS Options 158 652 7017 6300005Table 636. Status Selection Between SCPs and Servers 159 7017 6300005 653Figure 611. Single SCP/Server to UPS Status Cable Connections (Site UPS Installed) 160 654 7017 6300005Figure 612. Dual SCP/Server to UPS Status Cable Connections (Site UPS Installed) 161 7017 6300005 655Figure 614. Standalone (PRC1000i) UPS to SCP CablingPrimary SCP Box Redundant SC P Cable 7015 5403-002 To UPS 2 Domain 1 Domain 0U UKMLPT Box To UPS 1 7015 7789-001 Cable * * * Figure 613. SCP to UPS Status CableTo Interconnect Box 7015 6260 7015 5403-002 AC Input 3445 3720 AC to SCP Status 163 Section 7 Connecting Other Host Systems 165 Glossary171 Index
Also you can find more Unisys manuals or manuals for other Computer Equipment.