Configuring Additional Displays

Table 3–5. Guidelines for Configuring SCP Monitors and ODW Displays

Configuration

Guideline

 

 

Single-Domain/Non-

One monitor with keyboard and mouse is supplied with the system. It is shared

Redundant Dual Domain

with all other servers (up to 7 servers total) via the eight-way ST selector.

 

 

 

Up to six ODWs can be connected via the maintenance hub (Private LAN) and

 

the switching hub (Public LAN).

 

 

Redundant Dual-Domain

One monitor with keyboard and mouse is supplied with the system. It is shared

 

with the SCP in domain 0 and servers in both domains via the eight-way ST

 

selector.

 

 

 

One monitor with keyboard and mouse is supplied with the redundant console

 

and servers connected to domain 1. It attaches to the domain 1 eight-way ST

 

selector provided with the redundant console style.

 

 

 

Either monitor can be used for server windowing when not in use for SCP

 

functions.

 

 

 

Up to six ODWs with GUI capability can be connected via the maintenance hub

 

(Private LAN) and the switching hub (Public LAN).

 

 

System

Maint

Hub

(Private

LAN)

Switching

Hub

(Public

LAN)

Ethernet LANEthernet LAN

Client

Client

Supplied

Hub

ODW

Client

Supplied

Hub

0709

Figure 3–4. Typical Client Supplied Single ODW Arrangement

7017 6300–005

3–13

Page 79
Image 79
Unisys NX5820 manual Guidelines for Configuring SCP Monitors and ODW Displays, Configuration Guideline