Configuring Channels

 

Table 5–4. Guidelines for Configuring Channels

 

 

Rule

Description

 

 

Number of

Standard: 4 CMFs per CIOM (CMF 0, 1, 2, 3 per CIOM)

CMFs per CIOM

Maximum: Up to a maximum of 16 external CMFs per domain (32 CMFs per system) for

 

NX5820.

 

Up to a maximum of 20 external CMFs per domain (40 CMFs per system)for

 

NX5820 K.

 

 

CS-bus

A minimum of four CS-bus interfaces per CIOM are provided. When using up to 4 CIOMs

interfaces

with CS-bus connectivity, there are a maximum of 16 CS buses per domain for

 

NX5820. When using up to 5 CIOMs with CS-bus connectivity, there are a maximum

 

of 20 CS buses per domain for NX5820 K.

 

For all models, one additional CS-bus interface is required for each server attached to

 

the system. As an option, servers can be connected via the PCI thru card. Refer to

 

optional configurations in this section.

 

For the first CIOM in each domain, two of the four standard CMF/CS-bus interfaces

 

(CMF0/4 and CMF1/5) can service channels in the internal channel rack located

 

within the module assembly, plus additional external channels (up to 8 channels

 

maximum per CS-bus).

 

CS-bus interfaces can be connected to an external channel rack via optional package

 

styles listed in Table 5–1.

 

Each CS-Bus interface can service up to sixteen channel loads; however, see “Assigning

 

Channel Loads” earlier in this section. Channel loads should be balanced across

 

CMFs, CS-busses, and domains.

5–10

7017 6300–005

Page 98
Image 98
Unisys manual Guidelines for Configuring Channels, CS buses per domain for NX5820 K