York DY 060 manuals
Household Appliance > Air Conditioner
When we buy new device such as York DY 060 we often through away most of the documentation but the warranty.
Very often issues with York DY 060 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner York DY 060 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
36 pages 2.09 Mb
SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS TECHNICAL GUIDE DESCRIPTION 2 TABLE OF CONTENTSLIST OF TABLES343615-YTG-B-0308 Johnson Controls Unitary Products PRODUCT NOMENCLATURED Y 048 N04 A 2 A AA 2 0 1 2 4 A 3 3-5 Ton Sunline Magnum Model Number Nomenclature4 FEATURES5 343615-YTG-B-0308Johnson Controls Unitary Products Gas/Electric FIGURE 1 - UNIT CUTAWAY Electric/Electric and Heat Pump 6 FACTORY-INSTALLED OPTIONS7 FIELD-INSTALLED ACCESSORIES9 Johnson Controls Unitary Products TABLE 4: DY036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) TABLE 5: DY036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) 10 TABLE 6: DY036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET)TABLE 7: DY036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) 11 Johnson Controls Unitary Products TABLE 8: DY048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) TABLE 9: DY048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) 12 TABLE 10: DY048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET)TABLE 11: DY048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) 13 Johnson Controls Unitary Products TABLE 12: DY060 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) TABLE 13: DY060 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) 14 TABLE 14: DY060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET)TABLE 15: DY060 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) 15 343615-YTG-B-0308Johnson Controls Unitary Products TABLE 16: DY036 COOLING CAPACITIES (3 TON)2. 1. 16 Johnson Controls Unitary Products 16 TABLE 17: DY048 COOLING CAPACITIES (4 TON)17 Johnson Controls Unitary Products TABLE 18: DY060 COOLING CAPACITIES (5 TON) 18 TABLE 19: SUPPLY AIR BLOWER PERFORMANCE (DY036, 048, & 060 DIRECT DRIVE) SIDE DUCT APPLICATIONTABLE 20: SUPPLY AIR BLOWER PERFORMANCE (DY036, 048, & 060 DIRECT DRIVE) BOTTOM DUCT APPLICATION 19 Johnson Controls Unitary Products TABLE 21: STATIC RESISTANCES TABLE 22: ELECTRIC HEAT CFM LIMITATIONS 20 TABLE 23: ELECTRICAL DATA - DY036, 048 & 060 DIRECT DRIVE W/O POWERED CONVENIENCE OUTLET21 Johnson Controls Unitary Products 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. TABLE 23: ELECTRICAL DATA - DY036, 048 & 060 DIRECT DRIVE W/O POWERED CONVENIENCE OUTLET (CONT) 22 TABLE 24: ELECTRICAL DATA - DY036, 048 & 060 DIRECT DRIVE W/ POWERED CONVENIENCE OUTLET23 Johnson Controls Unitary Products 1. Minimum Circuit Ampacity. 2. Dual Element, Time Delay Type. 3. HACR type per NEC. TABLE 24: ELECTRICAL DATA - DY036, 048 & 060 DIRECT DRIVE W/ POWERED CONVENIENCE OUTLET (CONT) 24 TABLE 25: DY PHYSICAL DATATABLE 26: ELECTRIC HEAT CORRECTION FACTORS TABLE 27: VOLTAGE LIMITA TIONS Johnson Controls Unitary Products FIGURE 2 - TYPICAL FIELD POWER & CONTROL WIRING COOLING / HEATING (24 VOLT THERMOSTAT)TERMINALS TERMINALS UNIT TERMINAL STRIP TB1 24 VOLTTO REMOTE SENSOR 2TH040702224 IF USEDNOT USED ELECTRIC HEATER OR 2 STAGE GAS HEAT. COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGERH RC Y W G W1 C TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGERV YC GF UNITTERMINAL STRIPTB1 24 VOLT COOLING ONLY (24 VOLT THERMOSTAT)THERMOSTAT TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER ADD JUMPER 25 TYPICAL POWER WIRINGTYPICAL CONTROL WIRING 32 GUIDE SPECIFICATIONS
Also you can find more York manuals or manuals for other Household Appliance.