Display Trunk Members:<dis-tscu

PEN1 = 1-1-73-24;

 

 

 

 

 

H500: AMO TCSU

STARTED

 

 

 

 

+------------------------------------------------------------------------

 

 

 

 

 

+

PEN:

1-

1- 73- 1 INS: Y BOARD: TMDN64P

DEV: PRIB

TGRP: 100

+------------------------------------------------------------------------

 

 

 

 

 

+

TRKID

:

0001

TCCID

:

 

 

CCT

:

23

/0001

 

 

 

 

 

 

 

 

 

ACDATA :

0

DITIDX

: 0

LOCANA

:

ATNTYP :

CO

DPLN

: 0

REMANA

:

COPNO

:

100

ITR

: 0

SIDANI

: N

COSNO

:

100

LCRCOSD

: 1

SRTIDX

: 1

COTNO

:

100

LCRCOSV

: 1

TRTBL

: DIDCR

DEDSVC : NONE

FACILITY : *

 

 

+------------------------------------------------------------------------

 

 

 

 

 

+

7. Verification:

Making basic test calls, (direct dialing an extension) from each system verifies the connection. This application uses ESS5 and NI-2 standards. It is assumed that all features that are supported by these standards will work.

8. Conclusion:

This solution provides a means by which customers with traditional TDM based PBX communications networks, like the Siemens Hicom 300, can become IP Enabled without completely replacing their whole infrastructure. Enabling a gradual migration to a converged solution facilitates opportunities for enterprises using non-Avaya solutions to get familiar with applications and administration of the new Avaya platforms gradually. Enhancements to the enterprise network and the addition of services for new employees can be added to the new Avaya platform as the business needs continue to spawn opportunities for incremental change.

©2002 Avaya Inc. All Rights Reserved.

Avaya and the Avaya Logo are trademarks of Avaya Inc. All trademarks identified by ® and ™ are registered trademarks or trademarks, respectively, of Avaya Inc. All other trademarks are the property of their respective owners. The information provided in these Application Notes is subject to change without notice. The configurations, technical data, and recommendations provided in these Application Notes are believed to be accurate and dependable, but are presented without express or implied warranty. Users are responsible for their application of any products specified in these Application Notes.

Jsl

© 2002 Avaya Inc All Rights Reserved

IP Enabling Siemens

 

 

Hicom with Avaya

 

 

MultiVantage Solutions

LPH 11-27-02

 

22

Page 22
Image 22
2Wire g700, s8300 manual Verification, Conclusion, Display Trunk Membersdis-tscu