Determine If System Has Capacities:

 

 

 

 

 

 

 

<dis-dimen;

(Displays System Dimensions)

 

 

 

 

 

 

TYPE = cc;

 

 

 

 

 

 

 

 

 

 

DIS-DIMEN:CC;

 

 

 

 

 

 

 

 

 

 

H500: AMO DIMEN STARTED

 

 

 

 

 

 

 

 

 

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

NON-CONFIGURABLE PARAMETERS

 

 

 

 

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

TOTAL LINES

: ALLOC =

2750

LARGEST BLOCK =

2496

USED =

238

PHYSICAL LINES: ALLOC =

1368

MAX USED

=

203

USED =

203

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

 

CONFIGURABLE PARAMETERS

 

 

 

 

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

ALLOC /MAXUSED/ USED

 

 

ALLOC /MAXUSED/ USED

+------------------------------------

 

+------------------------------------

PRITRUNK:

 

2 /

1 /

1

+

 

 

 

 

 

TRUNK

:

49 /

49 /

27

 

 

T1SPAN

:

 

2 /

2 /

2

+------------------------------------

 

+------------------------------------

 

 

 

 

 

+

 

* = ALLOC-VALUE EXCEEDS ALLOC-RECMAX

 

 

 

 

 

 

 

 

( RECOMMENDED ALLOC-MAXIMUM )

 

FOR THIS SYSTEM TYPE

 

 

 

 

<dis-dimen:ltg;

 

 

 

 

 

 

 

 

 

 

 

 

 

DIS-DIMEN:LTG;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H500: AMO DIMEN STARTED

 

 

 

 

 

 

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

 

 

 

NON-CONFIGURABLE PARAMETERS

 

 

 

 

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

TOTAL LINES

: ALLOC =

 

2750

 

LARGEST BLOCK =

2496

 

USED =

238

PHYSICAL LINES: ALLOC =

 

1368

 

MAX USED

=

203

 

USED =

203

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

 

 

 

 

CONFIGURABLE

PARAMETERS

 

 

 

 

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

LTG: 1

 

ALLOC /MAXUSED/ USED

 

LTG: 1

 

ALLOC

/MAXUSED/

USED

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APILTG

:

32

/

0

/

 

0

LTGIDX

:

400

/

90 /

90

AUTOLTG :

0

/

0

/

 

0

NWCRLTG :

1

/

0 /

0

DHBUFLTG:

0

/

0

/

 

0

*OPTILTG :

72

/

4 /

3

DIG2LTG :

160

/

0

/

 

0

*OPTSTLTG:

72

/

4 /

3

*DIGILTG :

80

/

4

/

 

3

PRTRKLTG:

1

/

1 /

1

DILTG

:

96

/

4

/

 

3

RDTILTG :

18

/

0 /

0

DLPWLTG :

0

/

0

/

 

0

RP120LTG:

0

/

0 /

0

DSLTG

:

255

/ 115 /

115

RP240LTG:

0

/

0 /

0

DTILTG

:

281

/

30

/

30

RP400LTG:

0

/

0 /

0

DTIS0

:

0

/

0

/

 

0

*S0LTG

:

16

/

0 /

0

KSETLTG :

144

/

4

/

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

 

 

+

------------------------------------

 

 

 

 

+

 

* = ALLOC-VALUE EXCEEDS ALLOC-RECMAX

 

 

 

 

 

 

 

 

( RECOMMENDED ALLOC-MAXIMUM )

 

FOR THIS SYSTEM TYPE

 

 

 

 