1-13
To do… Use the command… Remarks
Enable information
output to the log buffer
info-center logbuffer [ channel
{ channel-number |
channel-name } | size buffersize ]*
Optional
By default, the switch uses
information channel 4 to output log
information to the log buffer, which
can holds up to 512 items by
default.
Configure the output
rules of system
information
info-center source { modu-name |
default } channel
{ channel-number |
channel-name } [ { log | trap |
debug } { level severity | state
state } ]*
Optional
Refer to Table 1-4 for the default
output rules of system information.
Set the format of time
stamp in the output
information
info-center timestamp { log | trap
| debugging } { boot | date |
none }
Optional
By default, the time stamp format
of the output log information is
date.
Follow these steps to set to output system information to the SNMP NMS:
To do… Use the command… Remarks
Enter system view system-view —
Enable the information
center info-center enable Optional
Enabled by default.
Enable information
output to the SNMP NMS
info-center snmp channel
{ channel-number |
channel-name }
Optional
By default, the switch outputs trap
information to SNMP through
channel 5.
Configure the output
rules of system
information
info-center source { modu-name |
default } channel
{ channel-number |
channel-name } [ { log | trap |
debug } { level severity | state
state } ]*
Optional
Refer to Table 1-4 for the default
output rules of system information.
Set the format of time
stamp in the output
information
info-center timestamp { log | trap
| debugging } { boot | date |
none }
Optional
By default, the time stamp format
of the information output to the
SNMP NMS is date.
To send information to a remote SNMP NMS properly, related configurations are required on both the
switch and the SNMP NMS. For the detailed configuration, refer to the SNMP-RMON part.