Figure 13 PGND screw on the chassis

Power Cords, Grounds and Cables 25

Figure 13 PGND screw on the chassis

(1)

1) Grounding screw

Connect the PGND to the earth ground using a PGND cable with a grounding resistance less than 5-ohm. If you install the chassis in a 19-inch standard rack, you must also ground the rack.

WARNING: Lightning strikes can damage your router and even the connected devices. For secure lightning protection, make sure that your router has a good ground connection when it is operating.

AC-Input Power Cord AC input range: 100 to 240 VAC, 50 to 60 Hz.

The following figure shows the power socket on an AC-powered router.

Figure 14 AC-input power socket