Installation and
BOX SIZE CAPACITY OF CASE SEALER
At its factory setting, the case sealer handles box sizes up to 620 mm [24.5 in] maximum height. If larger capacity is needed, the machine can be adjusted to accommodate boxes up to 725 mm [28.5 in] high. Refer to "Special
ELECTRICAL CONNECTION AND CONTROLS
The electrical control box, located on the lower right side of the machine frame, contains the
A standard three conductor power cord with plug is provided at the back of the electrical control box for 115 Volt, 60 Hz., 1.9 Amp electrical service. The receptacle providing this service shall be properly grounded. Before the power cord is plugged into 115 Volt, 60 Hz outlet make sure that all packaging materials and tools are removed from the machine. Do not plug electrical cord into outlet until ready to run machine.
Use of an extension cord is not recommended. However, if one is needed for temporary use, it must have a wire size of AWG 16 [1.5 mm dia], have a maximum length of 30.5 m [100 ft], and must be properly grounded.
WARNING – To prevent shock and fire hazard: Position extension cord
where it will be out of the way of foot or vehicle traffic. Extension cord is only for temporary use – do not use for a permanent installation.
Note – Machines outside the U.S. may be equipped with 220/240 Volt, 50 Hz systems or other electrical requirements compatible with local practice.
INITIAL
After completing the "Installation and
12