Special Set-Up Procedure

Special Set-Up Procedure

WARNING – Turn off electrical power and disconnect power cord from electrical supply before beginning Special Set-Up Procedure. If power cord is not disconnected, severe injury to

personnel could result.

Changing the Tape Leg Length

(From 70 to 50 mm [2-3/4 to 2 inch])

The following changes to the case sealer frame and upper/lower taping heads will allow the taping of boxes 90 mm [3.5 inch] minimum height.

CASE SEALER FRAME (Refer to Figure 6-1A)

1.Raise the upper head assembly by turning crank handle counterclockwise. Remove and retain the two stop bracket screws and washers from the normal position holes "A-A".

2.Move stop bracket down and secure with original fasteners through upper holes "A" in stop bracket. Relocate both right and left stop brackets.

Figure 6-1 – Case Sealer Frame Changes