Receiver Operations

Initial Settings

From the manufacturing facility, the receiver is configured as follows:

Line Locate Frequencies

Selection

Default

8 kHz

Always Enabled

Enabled

82 kHz

Always Enabled

Enabled

Power

Always Enabled

Enabled

Radio

Enable/Disable

Disabled

CATV

Enable/Disable

Disabled

CPS

Enable/Disable

Disabled

Sonde Locate Frequencies

 

 

512 Hz

Enable/Disable

Enabled

640 Hz

Enable/Disable

Disabled

33 kHz

Enable/Disable

Enabled

Units

inch or cm

Inch

Power Frequency

50 Hz or 60 Hz

60 Hz

Contrast

Up or Down

Middle

Depth Measurement

Live or One-Shot

One-Shot

The setup function will allow you to enable or disable additional locating and sonde frequencies.

Receiver Setup

Any of the available frequencies of the 3MDynatelAdvanced Pipe/Cable Locator 2220M can be activated or deactivated. When a frequency is activated, a check mark will appear beside the frequency in the middle of the setup screen. All frequencies that are activated in the setup menu, will be available in the locate screens.

When the Setup key is pressed, the receiver will cycle through the following screens.

Select the left/right arrow keys (← →) to cycle through the setup screens.

Contrast Adjust

Press the up or down arrows ( or ) to adjust the screen contrast.

Page 10
Image 10
3M 2220M manual Receiver Operations, Initial Settings, Receiver Setup, Line Locate Frequencies Selection Default