8
Receiver Operations

Initial Settings

From.the.manufacturing.facility,.the.receiver.is.configured.as.follows:.
Line Locate Frequencies Selection Default
8 kHz Always Enabled Enabled
82 kHz Always Enabled Enabled
Power Always Enabled Enabled
Radio Enable/Disable Disabled
CATV Enable/Disable Disabled
CPS Enable/Disable Disabled
Sonde Locate Frequencies
512 Hz Enable/Disable Enabled
640 Hz Enable/Disable Disabled
33 kHz Enable/Disable Enabled
Units inch or cm Inch
Power Frequency 50 Hz or 60 Hz 60 Hz
Contrast Up or Down Middle
Depth Measurement Live or One-Shot One-Shot
The.setup.function.will.allow.you.to.enable.or.disable.additional.locating.and.
sonde.frequencies..

Receiver Setup

Any.of.the.available.frequencies.of.the.3M.Dynatel.Advanced.Pipe/Cable.
Locator.2220M.can.be.activated.or.deactivated..When.a.frequency.is.activated,.
a.check.mark.will.appear.beside.the.frequency.in.the.middle.of.the.setup.screen..
All.frequencies.that.are.activated.in.the.setup.menu,.will.be.available.in.the.
locate.screens.
When.the.Setup.key.is.pressed,.the.receiver.will.cycle.through.the.following.
screens..
Select.the.left/right.arrow.keys.(← →).to.cycle.through.the.setup.screens.
Contrast Adjust
Press.the.up.or.down.arrows.( .or. ).to.
adjust.the.screen.contrast.