Specifications

21

Section 7: Specifications

Physical characteristics.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Electrical characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Temperature characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Performance characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Environmental conditions.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Physical characteristics

Dimensions of Control Unit9.3cm (3.7 in) high, extendable to 11.4 cm (4.5 in) high7.1cm (2.8 in) wide, 4.3 cm (1.7 in) deepWeight of Control Unit128 g (4.5 oz)Dimensions of Sensor4.1 cm (1.6 in) diameter, 0.5 cm (0.2 in) thickLength of the Sensor Cable400 cm (158 in)Classification

MEDICAL—GENERAL MEDICAL EQUIPMENT AS TO ELECTRICAL SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 60601-1; CAN/CSA-C22.2, No. 60601-1; ANSI/AAMI ES60601-1:2005 CSA-C22.2 No.601-1:08; EN60601-1; Control No.4HZ8

Classified under IEC 60601-1 Guidelines (and other national versions of the Guidelines) as Class II, Type CF, Defibrillation-Proof, Ordinary Equipment. Conforms to EN12470. Not suitable for use in the presence of flammable anesthetic mixtures with air or nitrous oxide.

Classified by Underwriters Laboratories Inc. with respect to electric shock, fire, and mechanical hazards only, in accordance with UL 60601-1, IEC 60601-1, and Canadian/CSA C22.2 No. 601.1. ANSI/AAMI ES 60601-1; 2005. EN60601-1. Classified under the Medical Device Directive as a Class IIb device.

Accuracy25°C to 43°C ± 0.2°CSensor MaterialMedical grade foam and adhesivePET flexible circuitRecommended Calibration CheckEvery 12 monthsSensor Shelf Life36 monthsDigital PortSerial output 0 [-12 to +12]Monitor Cable Port

Provides a resistance that corresponds to a YSI-400 thermistor at the displayed temperature. It is electrically isolated from the SpotOn control unit.