12
Installation and Set-Up (Continued)
BOX SIZE CAPACITY OF CASE SEALER
At its factory setting, the case sealer handles
box sizes up to 620 mm [24.5 inch] maximum
height. If larger capacity is needed, the machine
can be adjusted to accommodate boxes up to
725 mm [28.5 inch] high. Refer to "Special Set-
Up Procedure – Box and Machine Bed Height
Range", page 26. Note – Adjusting machine
to accommodate 725 mm [28.5 inch] high
boxes also increases minimum box size to
165 mm [6.5 inch].
ELECTRICAL CONNECTION AND CONTROLS
The electrical control box (with circuit breaker)
and "On/Off" switch are located on the lower left
side of the machine frame. See Figure 3-1. If
desired, for operator convenience, the "On/Off"
switch can be relocated to the right side of the
machine frame. A standard three conductor
power cord with plug is provided at the back of
the electrical control box for 115 Volt, 60 Hz.,
3.8 Amp electrical service. The receptacle
providing this service shall be properly
grounded. Before the power cord is plugged
into 115 Volt, 60 Hz outlet make sure that all
packaging materials and tools are removed from
the machine. Do not plug electrical cord into
outlet until ready to run machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5 mm diameter
[AWG 16 ], have a maximum length of 30.5 m
[100 ft], and must be properly grounded.
WARNING – To prevent shock and
fire hazard: Position extension
cord where it will be out of the way of foot
or vehicle traffic. Extension cord is only
for temporary use – do not use for a
permanent installation.
Note – Machines outside the U.S. may beequipped with 220/240 Volt, 50 Hz systems orother electrical requirements compatible withlocal practice.
INITIAL START-UP OF CASE SEALER
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for tape
loading and start-up to be sure case sealer is
properly adjusted to run boxes