14
Operation (Continued)
1. Turn electrical supply off and disconnect before servicing taping heads or performing any
adjustments or maintenance on the machine.
2. Do not leave machine running unattended.
3. Before turning drive belts on, be sure no tools or other objects are on the machine bed.
4. Keep hands and loose clothing away from moving belts.
5. Keep hands and clothing away from taping heads when machine is running. A box traveling
through the machine causes taping head rollers to retract when box enters and extend as box
leaves taping head.
6. Never attempt to work on any part of the machine, load tape or remove jammed boxes from the
machine while machine is running.
7. When feeding boxes to the machine by hand, push box in from end only – DO NOT PUSH WITH
HANDS ON ANY CORNER OF THE BOX.
8. Both the upper and lower taping heads utilize extremely sharp knife blades. The blades are
located under the orange blade guard which has the 'WARNING – SHARP KNIFE" label. Before
loading tape, refer to Figures 3-1 and 3-2 in Section II to identify the blade location. Keep
hands out of these areas except as necessary to service the taping heads.
9. Turn drive belts "Off" when machine is not in use.
10. Failure to comply with these warnings could result in severe personal injury and/or equipment
damage.
WARNINGS
CAUTION – Taping head weighs
approximately 7.2 kg [16 pounds]
without tape. Use proper body mechanics
when removing or installing taping head.
Emergency Stop Switch
The machine electrical supply can be turned off by
pressing the latching emergency stop switch. To
restart machine, rotate emergency stop switch
(releases switch latch) and then restart machine by
pressing "I" (On) button on side of machine frame.
Electrical "On/Off" Switch
The box drive belts are turned on and off ("Off"
button is red) with the electrical switch on the side of
the machine frame.
Tape Loading/Threading
See Section II, Pages 7 and 8
Note – The case sealer has a circuit breaker
located in the electrical enclosure on the lower left
side of the machine frame. If circuit becomes
overloaded and circuit breaker trips, unplug the
machine electrical cord and determine cause of
overload. After two minutes, open the electrical
enclosure and reset the circuit breaker by lifting
the reset lever. Close the electrical enclosure,
plug machine electrical cord into outlet and restart
machine by pressing "
I
" (On) button.
Note – If lower tape drum is mounted in alternate
lower outboard position, remove taping head from
machine bed by pulling straight up, insert
threading needle in taping head and replace
taping head. Install tape roll on drum (adhesive
on tape leg up), thread tape under knurled roller
on outboard mount, then attach tape to threading
needle and pull tape through taping head with
threading needle.