WARNING – USE CARE WHEN WORKING WITH COMPRESSED AIR.

Installation and Set-Up (Continued)

11.Box size capacity (height) – at its factory setting, the case sealer handles box sizes up to 620 mm

[24-1/2 inches] maximum height. If larger capacity is needed, the machine can be adjusted to accommodate up to 725 mm [28-1/2 inches] high boxes. Refer to "Special Set-Up Procedure – Outer Column Re-Positioning", page 35 for set-up information.

12.Drive Belt Height – drive belt assemblies can be raised 50 mm [2 inches] to provide better conveying of tall boxes. Refer to "Special Set-Up Procedure – Changing Drive Belt Height", page 33.

13.Pneumatic connection.

WARNING – USE CARE WHEN WORKING WITH COMPRESSED AIR.

The case sealer requires a 6.5 bar gauge pressure [95 PSIG] 75 liter/min @21°C, 1.01 bar [2.5 SCFM] compressed air supply. As shown in Figure 2-3 an on/off valve, pressure regulator, and filter are provided to service the air supply.

The main air supply line should be connected to the on/off valve by means of the barbed fitting and hose clamp provided on the outer side of the on/off valve as shown in Figure 2-3. The customer supplied air hose (5/16 inch [8 mm] ID) should be slipped over the barbed fitting and clamped tightly in place.

If another type of connector is desired, the fitting can be removed and replaced with the desired 1/4-18 NPT threaded connector.

Always turn the valve "Off" when air supply line is being connected or disconnected.

14.Electrical connection and controls – the electrical control box shown in Figure 3-1, contains the "On/Off" switch with pre-set breaker and can be located on either side of the machine frame for operator convenience. A standard three conductor power cord with plug is provided at the back of the electrical control box for 115 Volt, 60 Hz, 3.8 Amp electrical service. The receptacle providing this service shall be properly grounded. Before the power cord is plugged into 115 Volt, 60 Hz outlet, make sure red "Off" button is depressed and that all packaging materials and tools are removed from the machine. Do not plug electrical cord into outlet until ready to run machine.

Note – Machines outside the U.S. may be equipped with 220/240 Volt, 50 Hz systems, or other electrical requirements compatible with local practice.

Initial Start-Up of Case Sealer

 

After completing the "Set-Up" procedure, continue

 

through ""Operation", pages 15-24 to be sure case

Figure 2-3 – Pneumatic Connection

sealer is properly adjusted to run product.