27
Special Set-Up Procedure (Continued)
WARNING – Upper assembly weight is
approximately 35 kg [75 lbs]. Lift with
hoist or be sure to have adequate help
available to physically lift upper assembly up
and out of outer columns.
Moving the outer columns to the upper set of
mounting holes increases the maximum box size
(height) handled by the case sealer from 620 mm
[24-1/2 inches] to 725 mm [28-1/2 inches]. Note –
this also increases the minimum box height from
120 mm [4-3/4 inches] to 210 mm [8-1/4 inches].
WARNING – It is recommended that no
less than two people assist on this set-
up or severe injury or equipment damage
could result.
WARNING – Turn off electrical power
and disconnect power cord from
electrical supply before beginning special
set-up procedure, if power cord is not
disconnected, severe injury to personnel
could result.
Box Height Range
(Outer Column – Re-Positioning)
To Re-position the outer columns:
1. Remove special nut from the bottom of each
column lead screw. Figure 5-4A.
2. Remove plastic column cap from the top of each
outer column as shown in Figure 5-4B.
3. Crank upper assembly up, out of plastic nuts.
Lift upper assembly up and out of outer
columns. Be careful not to damage lead screws.
Figure 5-4C.