ASSEMBLY INSTRUCTIONS

All 3M™ 6000 Series Full Facepieces equipped with t he 3M™ 6884 DIN Port Adapter (full facepiece assemblies 6700DIN, 6800DIN and 6900DIN) can be used in any of the following configurations:

Powered Air Purifying Respirator (PAPR)

3M™ GVP Belt-Mounted PAPR

3M™ Powerflow™ Face-Mounted PAPR

3M™ Breathe Easy™ Belt-Mounted PAPR Supplied Air Respirator (SAR)

3M™ Dual Airline

3M™ Air Control Devices – Continuous Flow(excluding W-3196 Air Regulating Kit and

stainless steel options)

Negative Pressure

3M™ Responder FR-64 Cartridge and CP3N Canister (Front-Mounted)

3M™ 2000 Series and 7093 Filters and 6000 Series Cartridges (Side-Mounted)

Whenever the air filtration/supply system, including responder canisters or cartridges, are attached to the center DIN port of the 6884 DIN Port Adapter Assembly, the 3M™ 7890 Full Face Plug must be removed from the center port and the two bayonet ports must be closed using 6880 bayonet caps and 6895 Inhalation Port Gaskets.

Note: Make certain 3M™ 6895 Inhalation Port Gaskets are in place on the facepiece bayonet connectors before installing filters, cartridges or breathing tubes.

3M™ 6000 Series Cartridge (Side-Mounted) Assembly

1.Align the cartridge notch with the small solid bayonet lug on facepiece and push together.

2.Turn cartridge clockwise to stop (1/4 turn). Repeat with second cartridge. (Fig. 1)

3.Check that a 6876 breathing tube gasket (gray) and 7890 plug have been installed in the center DIN port.

Fig. 1

10