3M™ 6894 Nose Cup Assembly Replacement

The 6894 nose cup assembly consists of a nose cup and inhalation valves. It is designed to install onto the center adapter and comfortably fit over the respirator wearer’s mouth and nose to aid in purging exhaled breath and prevent lens fogging.

1.Remove the nose cup assembly by pulling away from center adapter inside facepiece (Fig. 12).

2.To replace, position nose cup assembly onto center adapter aligning arrows (Fig. 15).

Nose Cup Requirements

Use of the 3M™ 6894 Nose Cup Assembly with the 3M™ 6000DIN Series Full Facepiece must be in accordance with the following table.

Nose Cup Use Requirements for 3M™ 6000DIN Series Fu ll Facepiece

3M™ Respirator

NIOSH Approved Only

NIOSH Approved Only

NIOSH Approved With

System

With Nose Cup

Without Nose Cup

or Without Nose Cup

 

 

 

 

Belt-Mounted

 

 

 

PAPRs

 

 

 

 

 

 

 

Powerflow™ Face-

 

 

 

Mounted PAPR

 

 

 

 

 

 

 

Supplied Air

 

 

 

6000 Series

 

 

 

Cartridges

 

 

 

2000 Series Filters

 

 

 

CP3N Canister

 

 

 

FR-64 Cartridge

 

 

 

Dual Airline

 

 

 

 

 

 

 

!WARNING

Failure to use or not use the 3M 6894 nose cup in accordance with the above requirements may adversely affect respirator performance and result in sickness or death.

20