6006 | Certain organic vapors, chlorine, hydrogen | |
|
| chloride, chlorine dioxide, sulfur dioxide, hydrogen |
|
| sulfide (escape only), ammonia/methylamine, |
|
| formaldehyde or hydrogen fluoride |
6009 | Mercury Vapor/Chlorine Gas | Mercury vapor or chlorine gas |
60921 | Organic Vapor/P100 | Certain organic vapors and particulates |
60922 | Acid Gas/P100 | Chlorine, hydrogen chloride, and sulfur dioxide or |
|
| chlorine dioxide or hydrogen sulfide (escape only) and |
|
| particulates |
60923 | Organic Vapor/Acid Gas/P100 | Certain organic vapors, chlorine, hydrogen |
|
| chloride, and sulfur dioxide or hydrogen sulfide |
|
| (escape only) or hydrogen fluoride and particulates |
60924 | Ammonia/Methylamine/P100 | Ammonia and methylamine and particulates |
60925 | Formaldehyde/Organic Vapor/P100 | Formaldehyde and certain organic vapors and |
|
| particulates |
60926 | Certain organic vapors, chlorine, hydrogen | |
|
| chloride, chlorine dioxide, sulfur dioxide, hydrogen |
|
| sulfide (escape only), ammonia/methylamine, |
|
| formaldehyde or hydrogen fluoride and particulates |
60928 | Organic Vapor/Acid Gas/P100 | Certain organic vapors, chlorine, hydrogen chloride, |
|
| and sulfur dioxide or hydrogen sulfide (escape only) |
|
| hydrogen fluoride and particulates 1 |
60929 | Mercury Vapor/Chlorine Gas/P100 | Mercury vapor or chlorine gas and particulates |
1.3M recommended for use against methylbromide or radioiodine up to 5 ppm with daily cartridge replacement.
Service Life of 3M™ 6000 Series Cartridges3M™ 6000 Series Chemical Cartridges should be used before the expiration date on cartridge packaging. The useful service life of these cartridges will depend upon activity of wearer (breathing rate), specific type, volatility and concentration of contaminants and environmental conditions such as humidity, pressure, and temperature. Cartridges must be replaced in accordance with an established change schedule or earlier if smell, taste or irritation from contaminants is detected.