6006

Multi-Gas/Vapor

Certain organic vapors, chlorine, hydrogen

 

 

chloride, chlorine dioxide, sulfur dioxide, hydrogen

 

 

sulfide (escape only), ammonia/methylamine,

 

 

formaldehyde or hydrogen fluoride

6009

Mercury Vapor/Chlorine Gas

Mercury vapor or chlorine gas

60921

Organic Vapor/P100

Certain organic vapors and particulates

60922

Acid Gas/P100

Chlorine, hydrogen chloride, and sulfur dioxide or

 

 

chlorine dioxide or hydrogen sulfide (escape only) and

 

 

particulates

60923

Organic Vapor/Acid Gas/P100

Certain organic vapors, chlorine, hydrogen

 

 

chloride, and sulfur dioxide or hydrogen sulfide

 

 

(escape only) or hydrogen fluoride and particulates

60924

Ammonia/Methylamine/P100

Ammonia and methylamine and particulates

60925

Formaldehyde/Organic Vapor/P100

Formaldehyde and certain organic vapors and

 

 

particulates

60926

Multi-Gas/Vapor/P100

Certain organic vapors, chlorine, hydrogen

 

 

chloride, chlorine dioxide, sulfur dioxide, hydrogen

 

 

sulfide (escape only), ammonia/methylamine,

 

 

formaldehyde or hydrogen fluoride and particulates

60928

Organic Vapor/Acid Gas/P100

Certain organic vapors, chlorine, hydrogen chloride,

 

 

and sulfur dioxide or hydrogen sulfide (escape only)

 

 

hydrogen fluoride and particulates 1

60929

Mercury Vapor/Chlorine Gas/P100

Mercury vapor or chlorine gas and particulates

1.3M recommended for use against methylbromide or radioiodine up to 5 ppm with daily cartridge replacement.

Service Life of 3M™ 6000 Series Cartridges

3M™ 6000 Series Chemical Cartridges should be used before the expiration date on cartridge packaging. The useful service life of these cartridges will depend upon activity of wearer (breathing rate), specific type, volatility and concentration of contaminants and environmental conditions such as humidity, pressure, and temperature. Cartridges must be replaced in accordance with an established change schedule or earlier if smell, taste or irritation from contaminants is detected.