3M™ GVP PAPR Assembly

Screw 3M™ GVP-123 breathing tube elbow adapter into the center port of the 6884 adapter assembly. User must follow User Instructions provided with the GVP Belt-Mounted Powered Air Purifying Respirator Assembly.

Fig. 6

3M™ Breathe Easy™ Turbo PAPR Assembly

Screw the threaded adapter on the 3M™ 520-01-77 Bre adapter assembly. User must follow User Instructions Assembly.

athing Tube into the center port of the 6884 Din port provided with the Breathe Easy™ Turbo PAPR

3M™ Powerflow™ PAPR Assembly

User must follow User Instructions provided with the Powerflow™ PAPR.

The Powerflow systems are not NIOSH approved for use with a nose cup. Use of a nose cup, may result in sickness or death.

The connection between the Powerflow™ PAPR assembly and the 3M™ 6000DIN Full Facepiece must be checked every time the unit is assembled or swiveled. This check should be performed outside the contaminated environment. Entering the contaminated area while the connection between the PAPR assembly and the facepiece is loose may result in sickness or death.

14