6
B. Topierce soft copper tubing, turn handle to the right (clockwise) several times until it
stops. The valve is now closed. Turning the handle to the left (counterclockwise) will open
the valve.
C. Assemble insert, plastic sleeve and compression nut as shown onto yellow tubing and
fasten securely to saddle valve.
4) Making Connections (Refer to Figure 6, Page 12)
A. Connectyellow1/4”tubingfromsaddlevalvetothe“Push-In”ttingontheleftsideofthe
bracketassembly.THEYELLOWTUBEMUSTGOUPANDTHROUGHTHEBASEOF
THEBRACKET.
B.Connect theblue1/4” tubingfromthebase ofthefaucet tothe“Push-In”tting at-
tached to the base of the shut-off meter.
Installing Filter Cartridge & Replacing Filter Cartridges
C. Inordertoensureproperperformance,itisessentialthat“Filter1”beinstalledonthe left
and“Filter2”ontherightsideofthebracketassembly.Usethecolor/numbercodedlabels
tomatch“Filter1”cartridgewith“Filter1”head.
D.Metershouldbesetat“Star t”.
5) Test System
A. Opencoldwatervalveunderthesink.
B. Thesystemwillpressurize.Checkforleaks.Ifanyleaksarepresent,immediatelyturnoff
water and refer to the Troubleshooting Section.
6) Flush Filter
A. Pressing down on the faucet lever will dispense water until you let go. Lifting up on the
lever will lock the faucet open.
B. Flush5gallonsthroughsystem(approximately10minutes).Atthispoint,thewaterwill
run clear. In rare cases, it may take a week or more for the residual air bubbles to be
completely eliminated.
C. The system installation is now complete and ready to ser ve filtered water.
Enjoy!
7) Procedure for Drilling Hole Through Porcelain/Enamel/Ceramic Sinks with Sheet Metal or Cast Iron Base
Recommended Tools:
 •VariableSpeedDrill
 •PorcelainCutterToolSet(9/16”size)
 •Plumber’sPutty
NOTE: It is important to understand this procedure before beginning.
To reduce the risk associated with property damage due to water leakage:
•InstallationandUseMUST comply with all state and local plumbing codes.
CAUTION
•Besuretoinstalltubingsotherearenosharpbendsandinstallenoughtubingforeaseofser-
vice.Refertotheencloseddiagram(Figure1,Page8)ontheuseof“Push-In”plasticttings.
•Failuretoroutetheyellowtubingthroughthebracketwillnotallowprotectiveshroudtobefas-
tened securely to the bracket.
IMPORTANT NOTES