GLOBUG LIGHTING SYSTEM —TROUBLESHOOTING (LAMPS)
Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the diagnosis based on the Lamp Troubleshooting (Table 4) information shown below.
If the problem cannot be remedied, please leave the unit just as it is and consult or company's service department.
TABLE 4. LAMP TROUBLESHOOTING
SYMPTOM | POSSIBLE PROBLEM | SOLUTION | |
|
|
| |
| Is plug securely connected? | Plug in correctly. | |
|
|
| |
| Are generator and light tower switched on? | Turn on switch. | |
|
|
| |
| Is lamp loose? | Screw lamp securely into socket. | |
|
|
| |
| Is contactor properly connected? | Connect disconnected contactor. | |
|
|
| |
| Are any other electric appliances (other |
| |
Lamp does not light. | than light tower) plugged into power | Unplug all other appliances. | |
source? |
| ||
|
| ||
|
|
| |
| Is generator voltage normal | Repair or replace generator. | |
| voltage - 120 VAC)? | ||
|
| ||
|
|
| |
| Is model of lamp compatible? | Use genuine MQ lamp. | |
|
|
| |
| Is lamp cool enough to light again? |
| |
| (Interval of 20 to 30 minutes is required | Wait for lamp to cool down. | |
| before turning on lamp again) |
| |
|
|
| |
| Is generator voltage normal | Repair or replace generator. | |
Lamp only lights for a | voltage - 120 V)? | ||
| |||
short time. | Is ambient temperature too high (more than | Move lamp where there is proper | |
| |||
| 104 °F (40 °C)? | ventilation. | |
|
|
| |
Balloon does not | Is fan motor (blower) working properly? | Check or repair fan motor (blower). | |
|
| ||
inflate. | Is balloon envelope defective? | Repair or replace balloon envelope. | |
| |||
|
|
|
PAGE 38 — GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06)