PAGE 20 — GLOBUG LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #3 (03/22/06)
GLOBUG LIGHTING SYSTEM — GENERAL INFORMATION
The Multiquip GloBug Lighting System is a general purpose
floodlight tower intended for emergency and remote lighting
conditions. The GloBug can be powered by a variety of
Multiquip's series generators. Power requirements for running
the GloBug are 120 VAC, 60 Hz @ 9.5 amps. The GloBug
can be powered by any MQ portable generator with an output
of 2.9 kW or greater.
The lighting system of Multiquip's GloBug Lighting System
is comprised of one "Metal Halide" 1000 watt lamp. This
lamp has an output of 112,000 lumens. Typical lighting
coverage is in excess 150 ft. (45.72 meters) in a 360 degree
pattern.
Located underneath the generator support platform is a
weather resistant ballast box that contains the ballast for
starting the floodlight. The floodlight is activated by an
ON/OFF switch located at the base of the mast.
For ease of service or transport, the floodlight is equipped
with a quick-disconnect connector that allows the lamp fixture
to be removed quickly. This feature is extremely useful during
transport of the lighting system over rough terrain. It is always
best to remove the floodlight and pack it safely so it will not
be damaged.
ALWAYS make sure the
area above GloBug is
open and clear of
overhead power lines
and other obstructions.
The tower extends in
excess of 16.5 ft. (5
meters). Contact with
overhead powerlines or
other obstructions could
result in equipment
damage,
Serious Injury or Death
!
DANGER - GloBug Overhead Obstructions
ACCIRCUIT
BREAKER
ACCIRCUIT
BREAKER
120/240V
120/240V
30A
30A
120V
30A20A
20A
0N
OFF
IDLE
CONTROL
OPERATION
SWITCH
ON
OFF
FULLPOWER
SWITCH
120V
120V/240V
120
V
OFF
OFF
21A
21A
GA-6H
6000
The lighting system can be raised vertically in excess of 31.5 feet
(9.6 meters) by means of a manual winch. The tower tensioning
system is designed to provide the necessary tension to safely
control the pivot of the tower. Outriggers must always be deployed
prior to raising the mast.
NOTE
All information related to the
generator will be referenced in a
separate (supplied) "Operation
and Parts Manual". Operation
and maintenance of the generator
will not
be referenced in this
manual.
Alarm Buzzer
The GloBug is equipped with a "Balloon Alarm" feature. This
alarm will sound if the lamp is on and the balloon attempts to
make contact with the
hot!
surface of the lamp . This alarm
is intended to inform the operator that a potential burn hazard
exits between the lamp surface and the balloon material.
Always allow the lamp to cool down before removing the AC
power from the GloBug. In the event the balloon begins to
deflate during normal operation, immediately place the
GloBug's ON/OFF switch in the OFF position.
Please read carefully the specified
generator manual that will accompany your
GloBug lighting system. This manual will
explain how to operate and maintain the
generator.
Balloon Envelopes
The GloBug can be configured with a variety of balloon
envelopes (canopy). Please contact the MQ sales department
for the balloon of your choice. The GloBug, Model GB114BC
comes with the standard balloon (BAL-120).