2.3 ALARM In/Out

NO CONNECTION

RECORD IN

 

5

4

DISK FULL

 

 

ALARM OUT

 

 

GROUND

3

2

1

9 8 7 6

NO CONNECTION

NO CONNECTION

NO CONNECTION NO CONNECTION

THIS FIGURE IS LOOKED FROM THE REAR VIEW

1.GND: Ground Contact.

2.ALARM OUT (OUTPUT): This is an alarm output trigger. Connect this to external devices such as

buzzers or lights. (

 

 

5V

)

 

 

0V(Active)

 

 

3.DISK FULL (OUTPUT): This is a disk full output trigger. Connect this to external devices such as

 

 

 

5V

 

buzzers or lights. (

 

0V(Active)

)

 

4.NO CONNECTION

5.RECORD IN (INPUT): This pin connects to a record trigger device for starting a record.

(

5V 0V(Active) )

6.NO CONNECTION

7.NO CONNECTION

8.NO CONNECTION

9.NO CONNECTION

10

Page 12
Image 12
Maxtor NVR-2028 manual Alarm In/Out, This Figure is Looked from the Rear View, No Connection