3M Dynapro ET 350 Monitor User’s Installation Guide

Step 2:Make connections

6.Remove the bracket, find the DIP-Switch on the board, and move the switch to the on position.

7.Replace the bracket and screws and close the enclosure.

To connect communications cables, follow these steps:

1.If the monitor has a hatch, the hatch must be open to access connectors. Remove the four #6-32 Phillips screws affixing the hatch to the monitor and open the hatch cover. For an illustration of the locations of these screws, refer to Figure 13 on page 38.

2.Make sure that the monitor and host computer are powered off.

3.Connect one end of the combination keyboard, video, and mouse cable to the local unit of the KVM extender and the multiple connectors on the other end of the cable to the corresponding connectors on the host computer.

4.Connect the serial cable between the KVM local unit and the host computer.

Important

To help ensure optimal performance and to reduce the effect of interference, route the CAT5 cable away from generators, motors, compressors, fluorescent lights, and other cables.

5.Interconnect the remote unit (in the ET 350 monitor enclosure) and the local unit of the KVM extender using industry-standard structured cabling (Category 5 UTP or STP, 4-pair) terminated with RJ-45 male connectors. The appropriate connectors on the remote and local units are labelled CAT5 (Figure 23). For information on pinning/pairing the interconnecting cable, refer to Appendix C.

60