3M Touch Systems Proprietary Information
6
Installation Addendum
Moisture deflector
25-foot serial/VGA cables
50-foot serial/VGA cables
Security hardware (including security screws)
Note: A NEMA 4X panel gasket mounting kit ships with
all ET 355 monitors.
For details on the options, refer to the ET350 Monitor
User’s Installation Guide.
Specifications,certifications, and standardsThe specification and certification information bel ow
shows only points that apply to the ET 355 monitor and is
different from specifications and certifica tions that appear
in the ET 350 Monitor User’s Installation Guide and the
Installation Addendum for the ET 350 Mo nitor wi th Heater
and ET 355 Monitor HL with Heater.
For additional details on specifications, standards, and
certifications, refer to the ET 350 Monitor User’s
Installation Guide and, if you have an ET 35X monitor with
heater, the Installation Addendum for th e E T 350 Monitor
with Heater and ET 355 Monitor HL with Heater.
AC or DC power supply specifications
Certification marks and standards for
ET 355 Monitor HL
3M Touch Syst ems support
services
3M Touch Systems provides extensive support services
through our web site and technical support organization.
Visit www.3Mtouch.com, to download touch screen
software and drivers, obtain regularly updated technical
documentation on 3M Touch Systems products, and learn
more about our company.
Whenever you contact Technical Support, please provide
the following information:
Part number and serial number
Current driver version
Important
All options, includ ing VGA and serial cables, must be
considered in the end product.
Wiring methods must be considered in the end product.
Consider conducting a he at in g te st in t he en d pro duc t of whi ch
the ET 355 monitor is a part.
Power source: 3 terminal strip
Marks for ET 355 Monitor HL with AC Power Supply
UL recognized component1
cUL
CE
Class I Division 2; Groups A, B, C, D; T6
Class II Division 2; Groups F, G; T6
Marks for ET 355 Monitor HL with DC Power Supply
UL Recognized component1
cUL
CE
Class I Division 2; Groups A, B, C, D; T6
Class II Division 2; Groups F, G; T6
Class I Zone 2
Ex II 3 G/D
DEMKO 02 ATEX 021046 U; EEx nC IIC
Standards
UL recognized component1 for Pollution Degree3
environments if:
installed and tested with panel gasket in an enclosure that
meets NEMA 4X/IP 66 ratings;
installed with the NEMA 4X hatch kit
UL 60950; Safety Information Technology Equipment
CSA 22.2 No. 6095 0; Safety of Information Techno logy
Equipment
EN60950; Safety of Information Techno logy Equipment
USR (U.S. Recognized) — UL 60950
UL 1604: Electri cal Equipm ent for U se in Cl ass I and I I, Divis ion
2 and Class III Hazardous (Classified) Locations.
CSA 22.2 No. 213- M1987: Non-Incendi ve Electrical
Equipment for Use in Class I, Division 2 Hazardo us Locations.
UL 2279, Pt. 15; Standard for Electrical Equipment for Use in
Class I, Zone 0, 1, and 2 Ha zardous (Classified) Locations
CSA-E79-15; Electrical Apparatu s for Explosive Gas
Atmospheres
EN50021; Electrical Apparatus for Potentially Explosive
Atmospheres
EN50281; Electric al Apparatus for Us e in the Presence of
Combustible Dust
1For use in Pollution Deg ree 3 environments if install ed with the
NEMA 4X hatch kit or the NEMA 4X panel gasket in a UL Listed
enclosure that meets NEMA 4X/IP66 rating.