3M™ Super Close Projection System SCP712 | Operator’s Guide |
Picture Menu – Advanced
The Picture Menu with the Advanced option selected, shown below, is used to adjust the projected image for Computer and Component inputs only.
Picture | Input Source: Computer 1 | |
Over Scan | 97 | ···········●············ |
Color / Brightness | 10 | ·······················● |
Horizontal Position | 0 | ···········●············ |
Vertical Position | 0 | ···········●············ |
Frequency | 0 | ···········●············ |
Phase | 0 | ···········●············ |
Reset
Feature | Description | Range | Default | |
Over Scan | Adjust cropping of image boundaries from 90th to 100th | Video = 97 | ||
percentile (increments of 1 percent) | VGA = 100 | |||
|
| |||
Brightness / | Adjust the white peaking value of the DMD. | Computer = 10 | ||
Color | (0 = lowest white peaking value, 10 = highest value) | Video = 3 | ||
| ||||
Horizontal | Adjust horizontal position of projected image | N/A | 0 | |
Position | (Only for Computer 1 or Computer 2 input source) | |||
|
| |||
Vertical | Adjust vertical position of projected image | N/A | 0 | |
Position | (Only for Computer 1 or Computer 2 input source) | |||
|
| |||
Frequency | Adjust the horizontal width of the projected image | 0 | ||
(Only for Computer 1 or Computer 2 input source) | ||||
|
|
| ||
Phase | Adjust clock phase to reduce image distortion | 0 | ||
(Only for Computer 1 or Computer 2 input source) | ||||
|
|
| ||
Reset | Reset values in Advanced Picture menu only | N/A | N/A |
♥ 3M 2008. All Rights Reserved. | 16 |