self-test, go to next paragraph “Software installation”. If the Ethernet is not available, Network Camera will switch to wireless LAN mode.

To install in wireless LAN

If the Ethernet is not available while power on, the Network Camera will search for any access point with the SSID “default”. Once any access point is found, the LED will turn green to wait for installation. If the network environment cannot meet the default settings, install Network Camera in Ethernet to proceed with wireless LAN configuration.

The Network Camera provides a general I/O terminal block with one digital input and one relay switch for device control. Pin 1 and pin 2 can be connected to an external sensor device and the state of voltage will be monitored from the initial state 'LOW'. The relay switch of pin 3 and pin 4 can be used to turn on or off the external device.

Consult with the dealer of the peripherals for correct installation.

1

DI-

INPUT (Initial state of DI is low)

2

DI+

INPUT (Max. 50mA, 12VDC)

3

SW_COMMON

OUTPUT (open from SW_OPEN at initial state)

 

 

(close with SW_OPEN when set DO to ON)

4

SW_NOPEN

OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC

- 7 -

Page 8
Image 8
4XEM IPCAMWL40 manual To install in wireless LAN