sedIMent trapsAsedimenttrapshouldbeinstalledasclosetothegasinletofthewater
heateraspracticalatthetimeofwaterheaterinstallation.Thesediment
trapshouldbeeitherateettingwithacappednippleinthebottom
outletorotherdevicerecognizedasaneffectivesedimenttrap.
Contaminantsinthegaslinesmaycauseimproperoperationofthe
gascontrolvalvethatmayresultinreorexplosion.Beforeattaching
thegaslinebesurethatallgaspipeiscleanontheinside.Totrapany
dirtorforeignmaterialinthegassupplyline,adripleg(sometimes
calledasedimenttrap)mustbeincorporatedinthepiping.Thedrip
legmustbereadilyaccessible.Installinaccordancewiththe“Gas
Piping”section.Refer to the current edition of the National Fuel
GasCode(ANSIZ223.1/NFPA54)ortheNaturalGasandPropane
InstallationCode(CAN/CSAB149.1).
fIllInG the water heaterNeverusethiswaterheaterunlessitiscompletelyfullofwater.Toprevent
damagetothetank,thetankmustbelledwithwater.Watermustow
fromthehotwaterfaucetbeforeturning“ON”gastothewaterheater.
Tollthewaterheaterwithwater:
1. Closethewaterheaterdrainvalvebyturningthehandletotheright
(clockwise).Thedrainvalveisonthelowerfrontofthewaterheater.
2.Openthe cold water supply valve to the water heater.
note: the cold water supply valve must be left open when
the water heater is in use.
3. Toinsurecompletellingofthetank,allowairtoexitbyopeningthe
nearesthotwaterfaucet.Allowwatertorununtilaconstantowis
obtained.Thiswillletairoutofthewaterheaterandthepiping.
4. Checkallwaterpipingandconnectionsforleaks.Repairasneeded.
ventInGvent pIpe terMInatIonThefirststepistodeterminewheretheventpipewillterminate.
SeeFigures19,20,and21.Theventmayterminatethrougha
sidewallasshowninFigure19orthroughtheroofasshownin
Figures20and21.
Theventsystem must terminate so that proper clearances
aremaintained as cited in local codes or the current
editionofthe National Fuel Gas Code, (ANSI Z223.1, 12.9.1
through12.9.4)or the Natural Gas and Propane Installation
Code(CAN/CSA-B149.1).
Instructionsonproperinstallationthroughasidewallareprovided
inFigures15A,15B,15C,and15D.
Planthevent system layout so that proper clearances are
maintainedfromplumbingandwiring.
Ventpipesservingpower ventedappliancesare classifiedby
buildingcodesas“ventconnectors”.Requiredclearancesfrom
combustiblematerialsmust be provided in accordance with
informationinthismanualunderFACTS TO CONSIDER ABOUT
LOCATION and INSTALLING THE WATER HEATER, and with
the National Fuel Gas Code and local codes.