Residential Gas Water Heaters
SERIES 200/201
| FIRST |
|
| BTU | RECOVERY | FOAM |
| DIMENSIONS IN INCHES |
| DRAFT | APPROXIMATE | |||
MODEL | HOUR | ENERGY | GALLON | INPUT | 90ºF RISE | THICKNESS | A | B | C | D | E | F | HOOD | SHIPPING |
NUMBER | RATING | FACTOR | CAPACITY | PER HOUR | GALLONS | (INCHES) | OUTLET | WEIGHT | ||||||
| GALLONS |
|
| NATURAL† | PER HOUR |
|
|
|
|
|
| (LBS) | ||
TALL MODELS |
|
|
|
|
|
|
|
|
|
|
|
|
| |
70 | .62 | 40 | 40,000 | 41 | 2 | 20 | 13 | 8 | 3 or 4 | 150 | ||||
88 | .62 | 50 | 40,000 | 41 | 2 | 61 | 22 | 13 | 8 | 3 or 4 | 165 | |||
SHORT MODEL |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
67 | .62 | 40 | 40,000 | 41 | 2 | 22 | 13 | 8 | 41 | 3 or 4 | 147 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Recovery capacity based on actual performance tests.
Water Connections – 3/4" on all models.
†Propane Gas – 37,000 BTU input for 50 gallon models & 36,000 BTU for 40 gallon models. For
Model Number (example:
ANODE ROD*
HOT
CONNECTION
Flammable Vapor Ignition |
| COLD |
|
Resistant Water Heaters |
|
| |
| CONNECTION | ||
|
| ||
A. O. Smith FVIR design meets or exceeds the American National Standards Institute standards |
| E |
|
(ANS Z21.10.1) that deal with the accidental or unintended ignition of flammable vapors, |
| C |
|
such as those emitted by gasoline. |
|
|
|
Feature a sealed combustion chamber with air intake filter and a flame arrestor built |
|
|
|
into the water heater base. In addition, a thermal cutoff (TCO) device, is designed |
|
|
|
to shut off gas flow to the burner and pilot if poor combustion is detected. |
|
|
|
T&P VALVE |
|
|
|
1/2" GAS |
| B | A |
|
| ||
CONNECTION | F |
| |
|
|
| |
|
| D |
|
| *Location for optional |
| |
|
| T&P Valve if ordered from factory. |
|
Maximum Hydrostatic Working Pressure: 150 PSI. |
If flammable vapors accidentally enter the combustion chamber, the arrestor is designed so flames burn off the top surface and can not escape down through the arrestor.
A. Industry standard thermocouple
B. Large View Port for easy burner inspection
C. 3600 combustion air filter
D. Thermal Cutoff (TCO) with manual reset
For Technical Information and Automated Fax Service, call
Created October 2008 | Page 2 of 2 | |
AOSRG45350 | ||
www.hotwater.com | ||
|