Installation
38 Instruction manual SGS3is
3.11.7 Connecting an extra error signal ('Alarm OUT' )Alarm OUT is a potential free terminal that is switched when an error is
detected. This can be used to signal errors, for example with a lamp. A 230 V
circuit can be directly powered. Other voltages require a relay prescribed by
the manufacturer.
1. Connect the phase cables (X1 and X2) to terminals 13 and 14 according to
the table (3.11.2"Pre paration"). If required, connect earth ( ) to terminal 15.
2. Fit the cable in the strain relief.
3. If you have no more connections to make:
- Fit the cap on the electrical terminal block.
- Fit the plastic covers onto the appliance.
3.11.8 Connecting communication cable to solar heating systemYou must connect a communication cable between the controllers of the
appliance and the solar heating system.
1. Connect the cables (X5 and X6) to terminals 1 and 2 as indicated in the
table(3 .11.2"Preparation").
2. Fit the cable in the strain relief.
- If you do not need to make any more connections:
- Fit the cap on the terminal block.
- Fit the covers onto the appliance.
3.12 Electrically connecting the solar heating system controllerTopics covered in this paragraph:
•Preparation
•Connecting the mains power
•Connecting pump station - modulating pump
•Connecting solar collector
•Connecting tank sensor
•Connecting top tank sensor
•Connecting communication cable
Optionally you can connect an extra head pump and Q/T sensor:
•Connecting extra head pump
•Connecting Q/T sensor
3.12.1 PreparationUndo the screws of the cap over the terminal block of the collector. This has the
following terminals:
Power n.a. Pump ON/OFF Modulating pump n.a.
LN- - - L
1NL
2NM-------
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1234123412341234
n.a.
n.a.
n.a.
n.a.
Power 5 V
n.a.
n.a.
Sensor S4
Flow signal
Sensor S1
Sensor S2
J3 J12 J13 J14
Semsor S1
Sensor S2
Sensor S3
Sensor S3