Instruction manual SGS 45
is
4 Conversion to a different gas category
Caution
The conversion may only by carried out by an authorised installation
engineer.
If the appliance must operate on a family of gases (LP gas or natural gas) or
other gas category than that for which the appliance has been set at the
factory, the appliance will have be adapted using a special conversion kit.
Caution
You must check the supply pressure and burner pressure once the
conversion is complete.
Orifice assembly
1. Isolate the appliance from the power supply (10.3 "Electrically isolating the
appliance").
2. Shut off the gas supply.
3. Undo the screws of the plastic covers.
4. Carefully remove the covers from the appliance.
Legend
Unused numbers are not applicable
2. three-part gas coupling
6. orifice with stamped figures
2
6
IMD-0225 R2