Instruction manual SGS 23
is
Dimensions (all measurements in mm unless otherwise indicated)
3.4.2 General and electrical specifications
General and electrical specifications
Dimen
sion
Description SGS 80 SGS 100
A Total height 2060 2060
C Position on pallet 530 530
D Appliance diameter 850 850
E Depth 1000 1000
F Width 900 900
G Diameter of flue gas outlet 130/200 130/200
H Height of flue gas outlet/air supply 2015 2015
Hx x position of flue gas outlet 310 310
Hy y position of flue gas outlet 440 440
K Height of gas connection 1855 1855
M Height of cold water supply 225 225
N Height of hot water outlet 2060 2060
Ny y position of hot water outlet 205 205
P Height of cleaning opening 290 290
R Height of drain valve connection 225 225
S Height of T&P valve connection 1425 1425
W Heig ht of condensation drain 240 240
1 Cold water supply connection (external) R11/2R11/2
2 Hot water outlet (external) R11/2R11/2
3 Gas control connection (internal) Rp3/4Rp3/4
4 Drain valve connection (internal) 3/4"3/4"
5 T&P valve connection (internal) 1 - 11.5 NPT 1 - 11.5 NPT
6 Cleaning/inspection opening 95x70 95x70
7 Condensation drainage connection (internal) Rp1 Rp1
DESCRIPTION Unit SGS 80 SGS 100
Capacity litres 460 460
Empty weight kg 480 480
Maximum operating pressure bar 8 8
Number of anodes - 2 2
Fan speed at ignition rpm 2790 3120
Working speed of fan rpm 5100 5700
Diameter of air restrictor mm 36.0 38.0
Heating-up time T = 45 oC minutes 18 14
Electrical power consumption W 600 690
Power consumption of solar heating system controller (max) W 700 700
Supply voltage
(-15% +10% VAC)
volts 230 230
Mains frequency Hz (± 1Hz) 50 50
IP class - 30 30