OPTIONAL HORIZONTAL VENT KIT #900124-7

OPTIONAL HORIZONTAL VENT KIT #900124-7

INSTALLATION #3

*Each part is stamped with a part number.

FIGURE 53

The opening through the wall should be cut at this time. If it hasnt been, refer back to that section.

1.Lock the elbow to the straight 3” flue pipe. Set the assembly in place on the end of the water heater’s flue collar.

FIGURE 54

2.Mark the flue collar at the slots in the elbow. Using a #22 drill bit, drill holes into the flue collar at the two slots and secure the elbow to the flue collar using the screws provided.

NOTE: Make sure elbow is properly aligned to opening in the outside wall.

FIGURE 57

5.Making sure the 6” diameter elbow is centered around the 3” diameter flue, secure the 6” diameter vent pipe using four sheet metal screws at the connection of the jacket top.

FIGURE 58

6.The standard kit includes a single piece of 3” flue and 6” vent pipe which will not be used in conjunction with the horizontal kit.

FIGURE 59

7.Slide the vent collar (to be installed later) over the 6” vent elbow.

FIGURE 55

3.Using the tube of sealant supplied, run an ample amount around the oval flare of the jacket.

FIGURE 56

4.First remove the 3” horizontal extension from the elbow. Starting with the long end (with four securing holes), place the 6” diameter vent elbow over the 3” diameter elbow. Bend the round end ovalto fit the flared oval end of the jacket top.

FIGURE 60

8.Place the water heater at the opening in the wall, at the predetermined clearance.