Manuals
/
A.O. Smith
/
Household Appliance
/
Water Heater
A.O. Smith
GDVS, XDVS, GDVH Tennessee Waltz Parkway, Ashland City, Tn, PHONE 1-800-433-2545 FAX
Models:
GDVH
XDVS
GDVS
1
28
28
Download
28 pages
48.55 Kb
21
22
23
24
25
26
27
28
<
>
Troubleshooting
Install
Warranty
Dimension
Maintenance
Optional Wire Grill
Vent Kit Assembly Components
Temperature Regulation
Safety
Using a #22 drill bit, drill holes 180 apart at the connection
Page 28
Image 28
500 TENNESSEE WALTZ PARKWAY, ASHLAND CITY, TN 37015
PHONE:
1-800-433-2545
FAX:
1-800-433-2515
www.aosmithwaterheaters.com / email: parts@hotwater.com
Page 27
Page 28
Image 28
Page 27
Contents
MAINTENANCE AND
OWNERS MANUAL
PAGE
3-19
GET TO KNOW YOUR WATER HEATER
TYPICAL INSTALLATION
REPLACEMENT PARTS
GENERAL SAFETY INFORMATION
INSTALLATION
VENT KIT ASSEMBLY COMPONENTS
EXTERNAL DAMAGE
CLOSED WATER SYSTEM
WATER POTABLE HEATING AND SPACE HEATING
GAS CONNECTIONS
VENTING
RELIEF VALVE
VENT PIPE TERMINATION
COMBUSTION AIR AND VENTILATION
OPTIONAL WIRE GRILL
VENTING CLEARANCES
FLUE EXTENSIONS
POSSIBLE EXTENSION COMBINATIONS
ALL INSTALLATIONS
VERTICAL EXTENSION KIT HEIGHT
HORIZONTAL EXTENSION KIT
CUTTING THE OPENING THROUGH THE OUTSIDE WALL
WATER HEATER ATTITUDE
STANDARD VENT KIT INSTALLATION #1
8. Slide the vent collar to be installed later over the 6” vent elbow
GALLON
EQUATION C - A -10” =
BTU’s in 1000’s
10. If “E” Dimension is less than 6 1/2” move to next step
7. Place the 3” elbow on the flue extension
Page
OPTIONAL HORIZONTAL VENT KIT #900124-7 INSTALLATION #3
14. Place the vent cap in the vent collar assembly
16. Move indoors to complete the assembly process
18. Using a #22 drill bit, drill holes 180 apart at the connection
point of the two 3” flue extensions. Then using 2 screws
EQUATION C - A - 10” =
OPTIONAL VERTICAL AND HORIZONTAL VENT KIT #900124-8 INSTALLATION #4
GALLON
BTU’s in 1000’s
13. Insert the 6” telescoping vent section into the wall
Page
HIGH ALTITUDE INSTALLATIONS
TEMPERATURE REGULATION
OPERATION
T & P VALVE AND PIPE INSULATION
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
FORCE
MAINTENANCE
HIGH TEMPERATURE LIMIT SWITCH Single-Use Type Energy Cut Off
TEMPERATURE & PRESSURE RELIEF VALVE
PILOT AND MAIN BURNER
ANODE ROD MAINTENANCE
CONDENSATION
CATHODIC PROTECTION - ANODE
DANGER The water CAN BE HOT
TROUBLESHOOTING
PROBLEM
SERVICE TO BE PERFORMED
POSSIBLE SOLUTION
LIMITED RESIDENTIAL GAS WARRANTY
SERVICE AND LABOR RESPONSIBILITY
CLAIM PROCEDURE
CONDITIONS AND EXCEPTIONS
Page
Page
Page
500 TENNESSEE WALTZ PARKWAY, ASHLAND CITY, TN
PHONE 1-800-433-2545 FAX