A.O. Smith GDVH, XDVS, GDVS owner manual EQUATION C - A -10” =, Gallon, BTU’s in 1000’s

Models: GDVH XDVS GDVS

1 28
Download 28 pages 48.55 Kb
Page 11
Image 11
EQUATION: C - A -10” = X

16.Go back indoors to attach inside collar to the inside wall. Place the collar against the wall. Secure to wall by using 4 long sheet metal screws.

FIGURE 30

NOTE: Screws are supplied; however, substitution may be necessary depending on the interior wall material.

17.Using the tube of sealant supplied, run an ample amount of sealant around the edge of the vent pipe where it is inserted through the inside collar to seal air drafts from wall.

FIGURE 31

OPTIONAL VERTICAL VENT KIT # 900124-6 WITH STANDARD HORIZONTAL VENT KIT INSTALLATION #2

Use the simple equation below, chart and drawing to find the length of expansion of the telescoping flue sections. Because of manufacturing tolerances, place the telescoping extension on the water heater and adjust the height (“X” Dimension) and mark the point. Once the length has been determined, lock the two sections together by drilling two holes (180° apart) in the pipe and securing with the screws supplied.

EQUATION: C - A -10” = X

 

*GALLON

*BTU’s in 1000’s

 

 

CAPACITY

NAT/L.P.

A

40

36/36

48-3/4

 

50

38/38

57-1/2

40

40/40

48-3/4

 

50

48/44

61

 

75

55 NAT.

63

*See models and rating plate attached to the water heater for specific model number and other detailed information.

ANY OPTIONAL VENT KIT

FIGURE 32

The opening through the wall should be cut at this time. If it hasn’t been, refer back to that section.

1.First it must be determined how far the vertical (3” dia.) telescoping flue sections are set and locked together using the two screws supplied as shown below.

FIGURE 33

FIGURE 34

NOTE: EACH PART HAS BEEN STAMPED WITH A PART NUMBER.

2.Set the vertical (3” diameter) telescoping flue section in place on the flue collar. Using a #22 drill bit, drill two holes (180° apart) and secure the vertical assembly to the flue collar.

FIGURE 35

3.Slide the 6” vent telescoping section apart to reveal the beads. Using the caulking supplied, fill the beads.

FIGURE 36

11

Page 11
Image 11
A.O. Smith GDVH, XDVS, GDVS owner manual EQUATION C - A -10” =, Gallon, BTU’s in 1000’s