Manuals
/
AB Soft
/
Computer Equipment
/
Network Card
AB Soft
1760 manual
Models:
1760
1
65
66
66
Download
66 pages
18.72 Kb
59
60
61
62
63
64
65
66
<
>
Specifications
Install
Circuit Diagram Menu
Dimension
Set Instruction Reset Instruction Output
Timing relay with on-delay, with and without random switching
Setting Clock
Pico Symbol
Safety
Power flow display
Page 65
Image 65
Page 64
Page 66
Page 65
Image 65
Page 64
Page 66
Contents
Pico Controller
Getting Results
Bulletin
Important User Information
electromechanical equipment. Safety Guidelines for the Application
Publication 1760-GR001C-EN-P - April
Table of Contents
Publication 1760-GR001C-EN-P - April
Table of Contents
Who Should Use this Manual
Preface
Related Documentation
Purpose of This Manual
Common Techniques Used in this Manual
Technical Product Assistance
Local Product Support
Your Questions or Comments on this Manual
Rockwell Automation Support
Publication 1760-GR001C-EN-P - April
Preface
Clever Switching and Controlling
Safety Information
Pico Controller
Chapter
Overview of Pico
Applications Everywhere
Mount on a Mounting Plate
Mount Pico
1760-L12DWD-xx
Connect Pico
Pico Inputs 1760-L12AWA-xx and 1760-L12NWA-xx
Pico Inputs1760-L12BBB-xx, 1760-L12BWB-xx and
Pico Outputs 1760-L12AWA-xx, 1760-L12BWB-xx
Pico Inputs 1760-L18BWB-EX and 1760-L18BWB-EXND
1760-L12DWD-xx, 1760-L12BBB-xx and 1760-L12NWA-xx
Publication 1760-GR001C-EN-P - April
Pico Inputs 1760-L20xxx
Pico Outputs 1760-L18xxx
Pico Inputs 1760-L18AWA-xx and 1760-L18NWA-xx
1-6 Pico Controller
Pico Inputs 1760-IB12XOB8
Pico Outputs 1760-L20xxx
Publication 1760-GR001C-EN-P - April
Pico Controller
Pico Inputs 1760-IA12XOW6I and 1760-IB12XOW6I
Pico Outputs 1760-IB12XOB8
1-8 Pico Controller
Publication 1760-GR001C-EN-P - April
Pico Outputs 1760-OW8
Pico Outputs 1760-IA12XOW6I and 1760-IB12XOW6I
Publication 1760-GR001C-EN-P - April
Pico Controller
Pico Operating Buttons
Pico Operating Principle
Button
Function
12-Point Status Display
Move Through Menus to Choose Values
1-11
Inputs Outputs
Menu Display
18-Point and 20-Point Status Display
Cursor Display
Circuit Diagram Menu
Circuit Diagram Symbols
RUN Power flow display
Menu Structure
Setting Clock
1-15
1-16 Pico Controller
Main Menu Setting Summer Time
Publication 1760-GR001C-EN-P - April
NONE
Main Menu with Password Protection
Password Entry
System Menu
Set Password
Password
Drawing a Circuit with Pico
Buttons for Drawing Circuit Diagrams
Operation of Pico
Chapter
Set the Menu Language
Set the Real Time Clock
Set the Time
Set Week Day and Time
Save setting
Winter/Summer Time Daylight Savings Time
Choose Pico Operating Mode
Selectable Start-up Behavior
The alternating RUN/STOP menu shows either
Contacts
Pico Circuit Diagram Elements
Pico Symbol
Relays
1760-L12BWB-xx
Retentive Actual Values
Retentive Relays
2-8 Drawing a Circuit with Pico
Set Instruction Reset Instruction Output
Instruction Output Instruction
On On
Draw Circuit in Circuit Diagram Menu
Diagram
Example Creating a Circuit Interconnect Contacts and Relays
Insert Contact “I1”
Choose Relay Coil “Q1”
Insert Contact “I2”
Draw Connection Between Contact and Relay Coil
Change Operating Mode
Test Circuit Diagram
Power flow display
2-11
2-12 Drawing a Circuit with Pico
Return to Status Display with ESC
“S1” on
“S2” on
Timing Relay
Function Relay Types
Time switch, weekday/time only in Pico models with clock
on Trigger Reseton on Timer Output
Trigger Reset Output
Trigger Reset Timer Output
Timing Relay with Off-Delay, with and without
2-14 Drawing a Circuit with Pico
Flash Frequency = 1/2 x setpoint on Trigger on Reset on Timer Output
Parameter Display for Timing Relays
Switch Function
Timer Number
Parameter Display for Counter Relays
Counter Relay
Count Input Direction Reset
Access Control
Parameter Display for Real Time Switches
Real Time Switch
Real Time Switch Number Week Days from - to
Parameter Display Access Control
Parameter Displays for Analog Comparators
Analog Comparator
Text Display
Conventional Circuit
Example Use a Function Relay
Select an Internal Marker Relay
Select Marker Contact and Connect to New Output Relay
Insert Timing Relay Contact
Select Parameter Access
Select Trigger Relay for Time
back to circuit diagram
Set “10 Seconds”
Connect Timing Relay Contact to New Output Relay
Significance of Logic Values
Basic Circuits
Negation NOR
Permanent Contact Unconditional Rung
Exclusive OR Circuit XOR
Series Connection AND
2-25
Motor Start/Stop Circuit
Alternatively
Publication 1760-GR001C-EN-P - April
Publication 1760-GR001C-EN-P - April
2-26 Drawing a Circuit with Pico
Chapter
Pico Interface Socket
Memory Module
Available Memory Modules
Load or Store the Circuit Diagram
Software Compatibility
PicoSoft
Find the Series Letter
Download the Software
Publication 1760-GR001C-EN-P - April
3-4 Pico Interface Socket
Physical Specifications
Specifications
Appendix A
Product Selection Table
Catalog Number
Line Power
Inputs
Outputs
Accessories
A-4 Specifications
Dimensions
107.5
541.77
Pico 1760-OW2 Expansion Module
Dimensions of the 1760-RM… Remote Processor modules
Specifications A-5
Publication 1760-GR001C-EN-P - April
Publication 1760-GR001C-EN-P - April
A-6 Specifications
Index
Page
Page
New Product Satisfaction Return
Installation Assistance
1.440.646.3223
Please contact your local Rockwell Automation representative for any