Acer 270 manual AC Adapter, 90Vac, Electrical Specification

Models: 270

1 127
Download 127 pages 20.6 Kb
Page 38
Image 38
Electrical Specification

LCD

Item

 

 

Specification

 

 

 

 

 

 

 

 

 

Supports colors

262K

262K

 

262K

262K

262K

 

 

 

 

 

 

 

Optical Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

Brightness control

keyboard

keyboard

 

keyboard

keyboard

keyboard

 

hotkey

hotkey

 

hotkey

hotkey

hotkey

 

 

 

 

 

 

 

Contrast control

No

No

 

No

No

No

 

 

 

 

 

 

 

Suspend/Standby

Yes

Yes

 

Yes

Yes

Yes

control

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply voltage for

3.3

3.3

 

3.3

3.3

3.3

LCD display (V)

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply voltage for

690

690

 

690

690

690

LCD backlight

 

 

 

 

 

 

(Vrms)

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Adapter

Item

 

 

Specification

 

 

Vendor & model name

ADAPTER ADP-65DB BG65W 3 PINS

 

 

 

 

Input Requirements

 

 

 

 

 

 

 

Maximum input current (A,

1.8 A

@

90Vac

@90Vac, full load)

0.9 A

@ 180Vac

 

 

 

 

Nominal frequency (Hz)

47 - 63

 

 

 

 

 

 

Frequency variation range (Hz)

47 - 63

 

 

 

 

 

Nominal voltages (Vrms)

90 - 265

 

 

 

Inrush current

The maximum inrush current will be less than 50A and 100A when the adapter

 

is connected to 115Vac(60Hz) and 230Vac(50Hz) respectively.

 

 

Efficiency

It should provide an efficiency of 84% minimum, when measured at maximum

 

load under 115V(60Hz).

 

 

 

 

Output Ratings (CV mode)

 

 

 

 

 

DC output voltage

19.0V including the effects of line voltage variation, load current, ripple and

 

noise

 

 

 

 

Noise + Ripple

300mvp-pmax (20MHz bandwidth) for resistor load

 

 

 

Output current

0 A (min.)

3.5A (max.)

 

 

 

 

Output Ratings (CC mode)

 

 

 

 

 

 

 

DC output voltage

19.0

 

 

 

 

 

 

Constant output

3.5A

 

 

 

 

 

 

Dynamic Output Characteristics

 

 

 

 

 

Start-up time

3 sec. (@115Vac)

 

 

Hold up time

6 ms min. (@120 Vac input, full load)

 

 

 

 

Over Voltage Protection (OVP)

25 V

 

 

 

 

Short circuit protection

Output can be shorted without damage, and auto recovery

 

 

Electrostatic discharge (ESD)

15kV (at air discharge)

 

8kV (at contact discharge)

 

 

 

 

Dielectric Withstand Voltage

 

 

 

 

 

Primary to secondary

4242 Vdc for 1 second

 

 

Leakage current

60uA at 254Vac

 

 

Regulatory Requirements

1. FCC class B requirements(USA)

2.VDE class B requirements(German)

3.VCCI classII requirements(Japan)

Chapter 1

33

Page 38
Image 38