Acer 5710G, 5310G manual Undetermined Problems

Models: 5710G 5310G

1 104
Download 104 pages 14.7 Kb
Page 91
Image 91
Undetermined Problems

Undetermined Problems

The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, whether a short circuit is suspected, or whether the system is inoperative.

Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU). NOTE: Verify that all attached devices are supported by the computer.

NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See “Power System Check” on page 71.):

1.Power-off the computer.

2.Visually check them for damage. If any problems are found, replace the FRU.

3.Remove or disconnect all of the following devices:

qNon-Acer devices

qPrinter, mouse, and other external devices q Battery pack

q Hard disk drive

qDIMM

qCD-ROM/Diskette drive Module

qPC Cards

4.Power-on the computer.

5.Determine if the problem has changed.

6.If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU.

7.If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU:

qSystem board

qLCD assembly

Chapter 4

87

Page 91
Image 91
Acer 5710G, 5310G manual Undetermined Problems