SG_TM800.book Page 28 Thursday, February 27, 2003 10:21 PM

AC Adapter

Item

Specification

 

 

Vendor & model name

Delta 75W ADP-75FB A(WPFC) 3P

 

Lite-on 75W PA 1750-02CA(WPFC) 3P

 

 

Input Requirements

 

 

 

Maximum input current (A,

<1.5A @ 90Vac

@90Vac, full load)

<1.125A @ 180Vac

 

 

Nominal frequency (Hz)

47 - 63

 

 

Frequency variation range (Hz)

47 - 63

 

 

Nominal voltages (Vrms)

100 - 240

 

 

Inrush current

The maximum inrush current will be less than 75A and 188A when the adapter is

 

connected to 100Vac(60Hz) and 240Vac(50Hz) respectively.

 

 

Efficiency

It should provide an efficiency of 83% minimum, when measured at maximum

 

load under 115V(60Hz)

 

 

Output Ratings

 

 

 

DC output voltage

+18.8V~20.0V including the effects of line voltage variation, load current, ripple

 

and noise

 

 

Noise + Ripple

400mvp-p(20MHz bandwidth) for resistor load

 

 

Output current

0~3.95A

 

 

Input rated voltage

100/240V

 

 

Input currentt

1.5A @90Vac for Delta / 1.125A @90Vac for Lite-on

 

 

Dynamic Output Characteristics

 

 

 

Turn-on delay time

3 sec.

 

 

Hold up time

5 ms min. (115Vac, input full load)

 

 

Over Voltage Protection (OVP)

29 V

 

 

Short circuit protection

Output can be shorted without damage

 

 

Electrostatic discharge (ESD)

+/- 15kV (at air discharge)

 

+/- 8kV (at contact discharge)

 

 

Dielectric Withstand Voltage

 

 

 

Primary to secondary

3000Vac (4242Vdc) 10mA for 1 second

 

 

Leakage current

100uA max (240Vac, 60Hz)

 

 

Regulatory Requirements

Internal filter meets:

 

1. FCC class B requirements

 

2. VDE 243/1991 class B requirements

 

3. CISPR 22 class B requirements

 

4. VCCI class II requirements

 

 

Power Management

Power Saving Mode

Phenomenon

 

 

Standby Mode

The Sleep indicator lights up

Waiting time specified by the System Standby value

 

or the operating system elapses without any system

 

activity.

 

Or

 

When the computer is about to enter Hibernation

 

mode (e.g. during a battery-low condition), but the

 

Hibernation file is invalid or not present.

 

 

 