Appendix C

AcceleRAID 352

Error Messages

Note

The firmware you are using may have these messages turned off. However, they are listed here for your reference.

Start-up Error Messages

The BIOS looks for any initialization message posted by the firmware during the start-up sequence. If a message is found, one of the following errors displays on screen and the installation process aborts.

AcceleRAID 352 fatal error--Memory test failed! AcceleRAID 352 fatal error--Command interface test failed!

AcceleRAID 352 hardware error--Run Diagnostics to pinpoint error

AcceleRAID 352 firmware checksum error--Reload firmware

Drive Check Error Messages

If the firmware finds a valid controller configuration, but it doesn't match the SCSI drives currently installed, one or more of the following messages display:

Unidentified device found at Channel=x Target=Y

Device identified for Channel=x Target=Y found at Channel=x' Target=Y'

SCSI device at Channel=x Target=Y not responding!’,0

If any of the above messages are displayed, the firmware will not proceed any further in the initialization process, except to find other mismatches. Then, the BIOS prints out the following:

AcceleRAID 352 Configuration Checksum error--Run configuration utility!